COMPONENT IDENTIFICATION

SW2

ON

8

7

6

5

4

3

2

1

SW3

SA1

SA2

ON

4

3

2

1

ON

8

7

6

5

4

3

2

1

SW1

1

2

3

4

5

6

5

4

3

2

1

0

9

8

7

6

5

4

3

2

1

0

9

8

7

6

SW6

ON

8:N.U

7:N.U.

6:KS5

5:KS4

4:KS3

3:KS2

2:KS1

1:KS0

RUN LED

ERR LED

Configuration Jack

Node Address Setting

Rotary SW (MSB)

Node Address Setting

Rotary SW (LSB)

Network

DIP SW

RT+

RT–

SD

T2

T1

■ 

FRONT VIEW

■ 

SIDE VIEW

Euro Type
Connector Terminal

 

FRONT ROTARY SW

• Node Address: SA1, SA2

Node Address is set in decimal.
(Setpoint adjustment: 00 – 99)

 

FRONT DIP SW

(*)Factory setting

• I/O Points: KS0, KS1, KS2, KS3 (SW6)

SW

I/O POINTS

64 POINTS

(64 words)

16 POINTS

(16 words)

8 POINTS

(8 words)

4 POINTS

(4 words)

KS0

OFF

ON

OFF

ON

KS1

OFF

OFF

ON

ON

KS2

ON

ON

ON

ON

KS3

OFF

OFF

OFF

OFF

• I/O Type: KS4, KS5 (SW6)

SW

I/O TYPE

INPUT/OUTPUT 

MIXED

OUTPUT ONLY

INPUT ONLY

KS4

OFF

ON

OFF

KS5

OFF

OFF

ON

Note:  All switches are ex-factory set to the positions OFF.  

Be sure to set appropriate I/O points and I/O type be-
fore commissioning the network module.  Be sure to 
set unused SW6-7 and 6-8 to OFF.

 

SIDE DIP SW

• Data Allocation: SW1, SW2

Data Allocation Type*

1

 must be assigned to each I/O module 

position to specify how many data areas (four types) are to 
be occupied by each.
Two bits from SW1 and SW2 are assigned to each posi-
tion, and data areas can be specified from the module No. 1 
through 8.  Setting for No. 9 and later modules is identical 
to No. 8.

SW ASSIGNMENT

MODULE NO.

SW1-1

SW1-2

1

SW1-3

SW1-4

2

SW1-5

SW1-6

3

SW1-7

SW1-8

4

SW2-1

SW2-2

5

SW2-3

SW2-4

6

SW2-5

SW2-6

7

SW2-7

SW2-8

8

SW SETTING

DATA ALLOCATION

OFF

OFF

1

ON

OFF

4

OFF

ON

8

ON

ON

16

*1.  Refer to the specifications of the related series for the Data 

Allocation Type of I/O modules.

• Dual Communication: SW3-1

When two network modules are mounted, one must be 
‘Main’ (OFF) network and the other must be ‘Sub’ (ON) net-
work.  For single communication, the network module must 
always be set to ‘Main’ (OFF).

SW

DUAL COMMUNICATION

MAIN

SUB

SW3-1

OFF (*)

ON

• Input Error Data: SW3-2

Hold:

 When the communication from an input module is lost 

due to the input module error, the network module holds the 
signal and stands by until the communication recovers.

Set to ‘0’:

 When the communication from an input module 

is lost due to the input module error, the network module 
outputs ‘0.’

SW

INPUT ERROR DATA

HOLD

SET

 ‘0’

SW3-2

OFF (*)

ON

• Status Data: SW3-3 

*

2

Status is assigned to the last 2 words of the input area.

SW

STATUS DATA

WITHOUT

WITH

SW3-3

OFF (*)

ON

*2. Not available with firmware version earlier than 1.02.

• LED Function: SW3-4

Functions assigned to the front RUN and ERR LEDs can 
be selected.

SW3-4

LED FUNCTION

RUN

ERR

OFF (*)

Green when normal

Green ON or blinking 
when abnormal

ON

Red when receiving

Red when transmitting