background image

2

www.m-locks.com

 

TANTUM BASIC / TANTUM MLS

1  

IMPORTANT INSTRUCTIONS

•  Before mounting the lock, please read the instructions for use carefully.
•  Ensure that you 

only 

program the lock when the 

safe is open

.

  After changing the code, always try the code several times with the safe door open.
• 

Only after several positive function tests (opening / closing) the safe door can be closed.

•  Each key entry is confirmed by an audible tone and visual signal. These signals are not referred to in  
  the description that follows.
•  You have a maximum of 10 seconds for each key entry. If you do not make an entry via the keypad  
  during this period of 10 seconds, the entry procedure will automatically abort. You then have to  
  start from the beginning.
•  After entering a valid code, you will hear two audible tones. An invalid entry will trigger a long tone.
•  If you accidentally enter an invalid code at the first attempt, you must wait 20 seconds before you    
  re-enter the code.
•  Our products fulfil the EN1300 requirements regarding resistance against electrostatic charge.   
  In fact it may happen that the electrostatic charge of a user exceeds the extreme value many times.  
  That’s why we are asking you to touch the metal surface of the safe for discharging before 
  operating the lock.

!

  

The certifications of our locks are valid only if used together with the entry units indicated on the  

respective certificates. As soon as an entry unit not specified on our certificates is used, the certifica-
tion of the lock expires immediately.

Содержание Tantum Basic

Страница 1: ...Made in The Netherlands Tantum Basic MLS Mounting instructions V02 EN...

Страница 2: ...cedure will automatically abort You then have to start from the beginning After entering a valid code you will hear two audible tones An invalid entry will trigger a long tone If you accidentally ente...

Страница 3: ...quires a 7 digit code that can be changed by the user With the main code user code s can be activated and deleted After entering a valid code a double signal sounds and the motor will retract the lock...

Страница 4: ...the factory The standard dimensions are 30x45x1 5 LxWxH in mm The lock loses its certification if you retrofit the drill protection yourself Depending on the area of application construction and resis...

Страница 5: ...ck bolt has to be limited to 1 kN E g by a preconceived breaking point Please contact your manufacturer if higher forces are needed Only use supplied screws to mount the lock In the LOCKED position th...

Страница 6: ...th the fasten ing points of the boltwork 6 FUNCTIONAL TEST As with all locks from M LOCKS this unit has a unique feature for checking the electronics both that of the input unit and that of the lock F...

Страница 7: ...ning Automatic Automatic Locking Automatic Push to Close Automatic Push to Close Blocking element Motor Motor Mounting dimensions Standard Standard Possible mounting positions 4 4 Tantum Basic Tantum...

Страница 8: ...M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands If you need some help please send an E mail to service m locks com We will be happy to help you...

Отзывы: