background image

7

www.m-locks.com

Tantum

V02

EN

Installation check

With door open, bring bolt work in LOCKED position:
•   Avoid continuous pressure on the lock bolt.
•  During the movement of the bolt work the cables should be clear of moving parts.

Only after several positive function tests (opening / closing) the safe door can be closed!

DATASHEET

NOTES

2021_V02_EN Errors and modifications reserved

Tantum Basic /

Tantum Basic anti drill

Tantum MLS

Tantum MLS anti drill

Opening

Automatic

Automatic

Locking

Automatic / Push to Close

Automatic / Push to Close

Blocking element

Motor

Motor

Mounting dimensions

Standard

Standard

Possible mounting positions

4

4

Tantum Basic /

Tantum Basic anti drill

Tantum MLS /

Tantum MLS anti drill

Power supply

9V Alkaline Duracell, Procell or Energizer block batteries

Software

Codes

2 (6 digits)

Up to 10 (6 or 7 digits)

Manager Codes

1

1

User Codes

1

Up to 9

Time delay / open window

01-99 min / 01–19 min

01-99 min / 1-19 min

Battery low signal

Yes

Yes

Volume adjustable

Yes

Yes

Silent alarm

Yes

Yes

Dual mode

-

Yes

Audit 200 events

-

Yes

Manipulation protection

5 minute lockout after 4 consecutive wrong codes

Содержание Tantum Basic

Страница 1: ...Made in The Netherlands Tantum Basic MLS Mounting instructions V02 EN...

Страница 2: ...cedure will automatically abort You then have to start from the beginning After entering a valid code you will hear two audible tones An invalid entry will trigger a long tone If you accidentally ente...

Страница 3: ...quires a 7 digit code that can be changed by the user With the main code user code s can be activated and deleted After entering a valid code a double signal sounds and the motor will retract the lock...

Страница 4: ...the factory The standard dimensions are 30x45x1 5 LxWxH in mm The lock loses its certification if you retrofit the drill protection yourself Depending on the area of application construction and resis...

Страница 5: ...ck bolt has to be limited to 1 kN E g by a preconceived breaking point Please contact your manufacturer if higher forces are needed Only use supplied screws to mount the lock In the LOCKED position th...

Страница 6: ...th the fasten ing points of the boltwork 6 FUNCTIONAL TEST As with all locks from M LOCKS this unit has a unique feature for checking the electronics both that of the input unit and that of the lock F...

Страница 7: ...ning Automatic Automatic Locking Automatic Push to Close Automatic Push to Close Blocking element Motor Motor Mounting dimensions Standard Standard Possible mounting positions 4 4 Tantum Basic Tantum...

Страница 8: ...M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands If you need some help please send an E mail to service m locks com We will be happy to help you...

Отзывы: