LX900 PROGRAMMING AND OPERATION

LDT, LDTB

11

MODES OF OPERATION

This controller has three (3) different modes of operation B2, C2, and TS (Timer Secure).  Factory default is B2 mode and 

the Timer To Close (TTC) is 0 seconds. Anytime the operator does not detect safety beams, it will automatically change to 

C2 mode. If the TTC is larger than 0 seconds, it will automatically change to TS mode.  There are 7 fixed delays for TTC – 

3, 15, 30, 45, 60, 90 and 180 seconds. To adjust the setting, hold in the TTC button (refer to diagram). Three LED's above 

the TTC button will indicate the current setting on the adjacent chart. After reaching 180 seconds, it will jump back to 0 

seconds (default) and the operator will revert to B2 Mode.  

C2 Mode

•  Momentary press of OPEN will open door.

•  Constant pressure required on CLOSE for the door to close. 

•  Single or three button transmitter will open or stop the door only.

B2 Mode

•  Momentary press of OPEN or CLOSE will activate door.

•  Single button - reverses a closing door, stops an opening door.

•  Transmitters activate operator same as wall stations.

TS Mode

•  Button function is the same as B2 mode.

•  Includes Timer to Close (TTC) function. The door will automatically close after set time expires.  Timer starts when 

door reaches the open limit. (When first entering TS mode or after power interruption, momentary press of OPEN will 

start timer if door is at OPEN limit.)

General Notes regarding Mode of Operations:

•  After power interruption the first  move is Open.

•  STOP button works in all modes of operation. If the 3 button wall station is not connected to the Control board or there 

is no jumper between COM and STOP, the motor will not run.

•  The Constant Pressure (CP) feature will work only from 3 and 1 button wired Wall Stations

•  The controller includes a Run Timer: a maximum amount of time the motor will run after receiving either open or close 

command. Factory default: 45 seconds. Not adjustable.

•  Open override means that the door may be reversed while closing by activating an OPEN button without the need to 

use the STOP button first (for all 3 Modes).

To reduce the risk of serious injury or death, follow these instructions carefully: 

•  Read and follow ALL instructions.

•  Keep fingers and other body parts away from all moving parts of the door and gate operator system 

while it is being operated.

•  Keep the radio controls away from children. Do not allow children to play with the controls.

•  Keep away from the door when it is in motion. Watch the door while it is moving until completely 

closed or opened.

•  Do not cross the path of a moving door.

•  Disable and locks and remove any ropes connected to the garage door to avoid entanglement and 

prevent damage to the system.

•  Do not make repairs to cable, springs, or other hardware; call a trained door systems technician. The system is 

under extreme tension and can cause serious injury or death.

•  Ensure that the door is properly operating and balanced. If not, call a trained door systems technician to make 

repairs.

WARNING

Содержание Napoleon Lynx LDT

Страница 1: ...ited duty applications not to exceed 12 cycles of opening and closing per hour NOT FOR RESIDENTIAL USE 9 5 16 15 1 4 UNLE DRA FINIS MATE DIM TO H O A PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF NAPOLEON LYNX ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF NAPOLEON LYNX IS PROHIBITED ...

Страница 2: ... actuated drum brake BEARINGS Ball bearing with hardened races DIMENSIONS WEIGHT OPERATOR HANGING WEIGHT 50 60 LBS DIMENSIONS Page 17 DISCONNECT Quick disconnect door arm for emergency manual door operation PHOTO EYES Included with Operator REVERSING EDGE Optional Electric or pneumatic sensing device attached to the bottom edge of door A REVERSING EDGE IS STRONGLY RECOMMENDED FOR ALL COMMERCIAL OP...

Страница 3: ...de 3 Install hex nuts on the bolts and tighten to secure the operator to the rail Chain Installation 1 With the trolley engaged in the chain tensioner use a master link to attach one end of the chain to the chain tensioner 2 Route the chain around the front idler sprocket and the drive sprocket on the operator and back to the other side of the chain tensioner Ensure the chain rides across the top ...

Страница 4: ...his line to the header where you marked the center of the door Figure 3 3 Ensure the header is suitable to mount the wall mount to If necessary reinforce the wall header with a mounting pad or suitable mounting brackets 4 Install the wall mount using suitable hardware The wall mount should be centered on the verti cal line that was drawn and 1 2 above the line that was drawn from the highest point...

Страница 5: ...t brace is recommended Figure 6 Door Attachment 1 Fully close the door 2 Install the door bracket to the top section of the door and in line with the rail using suitable hard ware Many installations except solid wood doors will require additional support for the door Refer to illustration Figure 6 3 Install the bottom hole of the curved arm to the door bracket using a 3 8 16 bolt 3 8 lock nut and ...

Страница 6: ...ack in the released position to prevent the trolley from reconnection automatically The trolley will release from the chain tensioner The door can now be raised and lowered manually 2 To Reconnect Door to Operator Pull the emergency release knob toward the door so that the disconnect snaps to the engaged position The next time the chain tensioner slides through the trolley the trolley will reconne...

Страница 7: ...afety Device TAKE UP REEL Take up reel should be installed 12 above the top of the door COIL CORD Connect operator end of coil cord to junction box not supplied fastened to the wall approximately halfway up the door opening LIMIT SWITCH ADJUSTMENT 1 To adjust limit nuts depress retaining plate to allow nut to spin freely After adjustment release plate and ensure it seats fully in slots of both nut...

Страница 8: ...he location of the power disconnect should be visible and clearly labeled ALL power and control wiring must be run in separate conduit To avoid damage to door and operator make ALL door locks inoperative Secure lock s in OPEN position If the door lock needs to remain functional install an interlock switch POWER WIRING CONNECTIONS 1 DO NOT INSTALL ANY WIRING WITHOUT CONSULTING THE WIRING DIAGRAM Th...

Страница 9: ...equipment as desired but so that the door will be in clear sight of the person operating the equipment and connect to the control board in accordance with the LX900 WIRING CONNECTIONS diagram Any control with a normally open N O isolated output contact may be connected in parallel with the OPEN button or to the momentary switch terminals More than one device may be connected in this manner Use 18 ...

Страница 10: ...rom the receiver these wires have no polarity and twist the stripped ends together Repeat on the second wire from each unit Connect the wires to the BEAM terminals Again polarity is not important 7 At this time you can reconnect the power to the operator The LEDs on both transmitter and receiver will be lit if installed and aligned properly the transmitter has a red LED and the receiver has a gree...

Страница 11: ...tes regarding Mode of Operations After power interruption the first move is Open STOP button works in all modes of operation If the 3 button wall station is not connected to the Control board or there is no jumper between COM and STOP the motor will not run The Constant Pressure CP feature will work only from 3 and 1 button wired Wall Stations The controller includes a Run Timer a maximum amount o...

Страница 12: ...t the transmitter has been programmed to the operator The controller will learn up to 20 Lynx transmitters Erase all transmitters To erase all remote transmitters press and hold the LEARN button for at least 15 seconds During this time observe that the learn LED will turn ON and after about 10 seconds the LEARN LED will flash three 3 times indicating that all the transmitters have been erased from...

Страница 13: ...ersing device Clutch Hub Fiber Disc Spring Adjustment Jam Nuts Washer Clutch Pulley On model LDTB a brake is supplied from the factory It is designed to stop and hold the door in position whenever power is removed from the motor On first installation the brake should not need adjustment The brake operation should be inspected every 3 months As the brake pads wear adjustments need to be made to mai...

Страница 14: ...manner and know how to use the manual disconnect operation of the door system MAINTENANCE SCHEDULE To avoid SERIOUS PESONAL INJURY or DEATH from electrocution disconnect ALL electric power BEFORE performing ANY maintenance WARNING 14 LDT LDTB IMPORTANT NOTE ITEM PROCEDURE EVERY 3 MONTHS EVERY 6 MONTHS Drive Chain Check for excessive slack adjust as needed Lubricate Sprockets Check for set screw ti...

Страница 15: ...ERMISSION OF NAPOLEON LYNX IS PROHIBITED PROPRIETARY AND CONFIDENTIAL 1 2 3 L3 L2 L1 Black White Blue Blue Thermostat Advanced Close Limit Open Limit Close Limit MA MB Red Red Capacitor Motor LDT Red Black White Black White 3 Wire Blue Orange Red Orange Red Blue Rev 06 08 15 Brake Solenoid if Required 115 Volt AC Single Phase Line In Ground to case with ground screw provided ...

Страница 16: ... BUTTON STATION OPEN STOP CLOSE OPEN CLOSE STOP COM WIRING FOR MULTIPLE 3 BUTTON STATIONS 3 BUTTON STATION OPEN STOP CLOSE MA STOP CLOSE BEAMS OPEN OPEN STOP CLOSE EDGE COM SINGLE COM LEARN TTC PROGRAM IF USING COAXIAL ANTENNA CUT PROVIDED ANTENNA NEAR CIRCUIT BOARD NOT POLARITY SENSITIVE NORMALLY OPEN SAFETY DEVICE OPTIONAL MOMENTARY SWITCH INTERLOCK WHEN NEEDED Rev 09 11 15 LX 900 Wiring Connect...

Страница 17: ...Door Height Plus 4 9 minimum 24 10 1 4 3 1 2 Highest Point of Door Travel 12 15 16 SHOP DRAWING LDT LDTB 17 ...

Отзывы: