ALL-SEAR CARE & USE/INSTALLATION
MODEL-SPECIFIC BTU OUTPUTS
MODEL
ROTISSERIE
PROSEAR™ 2
TOTAL INPUT
L30AS(F)R
1 @ 14,000
2 @ 23,000
60,000 Btu/Hr
L36AS(F)R
1 @ 14,000
3 @ 23,000
83,000 Btu/Hr
L42AS(F)R
1 @ 16,000
3 @ 23,000
85,000 Btu/Hr
MAXIMUM RUNS FOR ALL
APPLIANCES ON SUPPLY LINE
Run Length
3/4” Pipe (in feet)
Max BTU for all
Appliances on line
10
360,000
20
245,000
30
198,000
40
169,000
50
150,000
60
135,000
70
123,000
80
115,000
MODEL-SPECIFIC BTU OUTPUTS & MAX. RUNS FOR APPLIANCES
NOTE: IF A 1/2 INCH LINE IS USED
WITH NATURAL GAS IT SHOULD BE
NO LONGER THAN 12 FEET.