background image

34

  

 

|

 

 

ALL-SEAR CARE & USE/INSTALLATION

FINAL CHECKS

LEAK TESTING

Leak Test Procedure:

• Create a soapy solution of 1 part soap and 3 parts water. 
• Confirm that all control knobs are in the off position. 
• Turn on the fuel supply. For natural gas, turn the valve 

handle 1/4 turn to align with the gas flow.  

• For L.P., turn the cylinder valve knob counter clockwise 

one full rotation. 

• Apply the soap solution generously by paint brush or 

squirt bottle on all connections and fittings. 

• If bubbles appear to “grow” on any of the 

connections, you have a gas leak. IMMEDIATELY turn 
off the gas supply. 

Fixing a Gas Leak:

• Shut off the gas supply
• Turn all grill controls to the “ON” position to purge the 

grill of any gas build-up, then turn the controls back 
“OFF”. 

• Wash off the soapy solution with cold water and dry. 
• Tighten the loose joint, or replace the faulty part with 

manufacturer-recommended replacement parts. 

• DO NOT attempt to repair the L.P. cylinder valve if it is 

damaged. The only way to safely resolve a damaged 
cylinder is to REPLACE IT. 

• Repeat the leak test to ensure that no leaks are present.

LOW HEAT BURNER ADJUSTMENT

For ProSear™ 2 and side burners only!

DO NOT ADJUST THE ROTISSERIE BURNER. 

The ProSear™ 2 burners and side burners on your Lynx grill 
feature an adjustable low setting.

Fluctuations in gas pressure, gas conversion and even in the 
quality of the gas itself may affect burner performance at the 
“LOW” setting. It could be either too high or too low.  

GAS CONNECTIONS 

...

continued 

LP Connections

Make sure the LP cylinder valve is fully closed. It is possible 
for the valve to be open without releasing gas but, as soon 
as you start connecting the regulator, gas will leak from the 
connection.  

Insert the regulator inlet into the cylinder valve and turn the 
black coupler clockwise until the coupler is hand tight. Do 
not over-tighten this connection. 

To disconnect the coupler, first make sure the main cylinder 
valve is turned off. Grasp the coupler and turn counter 
clockwise. The inlet will then disengage. 

Always leak-test the connection after refilling or exchanging 
LP cylinders. (See INDEX: “Leak Test” for further details.)

GAS LINE PURGING

You should purge the gas line of air before attempting to 
light the grill.

Make sure all grill controls are in the “OFF” position. 

Slowly turn on the main gas supply.

Push in the rotisserie knob and confirm that the igniter 
is glowing. It is furthest from the fuel source and will 
completely purge the lines. It will take several seconds for 
the burner to light. 

Hold the knob ON for about 20 seconds to allow the air in 
the system to purge and the burner to light 

Wait at least 5 minutes after shutting off the control before 
attempting to light the burners.

To prevent fire or explosion hazard, DO NOT 
smoke or allow any potential source of ignition 
(sparks, electrical arcing, etc) in the area while 
performing a leak test. Leak tests should be 
conducted outdoors only. Never conduct a leak 
test using fire or flame.

DANGER!

Содержание All-Sear series

Страница 1: ...ALL SEAR CARE USE INSTALLATION MAKE THE MOST OF YOUR...

Страница 2: ...e components of the IR burner as an agent known to the state of California to cause cancer IF YOU SMELL GAS 1 Shut off all gas supply lines to the grill 2 Extinguish any open flames 3 Carefully open t...

Страница 3: ...u are using a portable propane cylinder is it connected and leak tested If not check the connection before continuing If yes please continue Do you know where your grill s main gas supply shut off val...

Страница 4: ...e trailers boats or any other moving installation Always have an ABC Fire Extinguisher accessible never attempt to extinguish a grease fire with water or other liquids Storing your grill Store your gr...

Страница 5: ...udes important safety tips and great hints for better grilling You ll want to keep it handy for easy reference Also at Lynx we enjoy hearing from our customers We like to hear about your successes but...

Страница 6: ...NX GRILL 19 Potential Problems 19 Contacting Lynx Customer Care 22 The Lynx Story 22 LYNX LIMITED WARRANTY 23 LYNX COMMON AREA LIMITED WARRANTY 24 BEFORE YOU START 26 If Shipment Arrives Damaged 26 Im...

Страница 7: ...use care manual covers the Lynx grill models listed below Some features and options will vary based upon the model that you purchased LYNX GRILL MODELS USE CARE GUIDELINES BUILT IN FREESTANDING L30ASR...

Страница 8: ...cause flare ups Internal fires or damage caused by them or by the grill being left unattended while cooking are not cov ered under the terms and conditions of our warranty 12 Never grill without the...

Страница 9: ...exclusive patent pending Heat Stabilizer that will deflect wind and in most cases prevent this situation But there are a few things you can do to further prevent the possibility of improper heat build...

Страница 10: ...ne cylinder it is securely connected and leak tested See INDEX Cylinder Retention Instructions for details you know where the main gas supply shut off is located the burners are seated properly in the...

Страница 11: ...d then turn the knob to the LITE position After ignition CONTINUE HOLDING THE CONTROL KNOB IN for 30 to 60 seconds During this time the thermocouple will heat up and the safety valve will remain open...

Страница 12: ...light the burners use the lighting rod to insert a lit match through the cooking grate Push and turn the corresponding burner control knob to LITE If the burner doesn t light within 5 seconds turn the...

Страница 13: ...foods are placed directly over the heat source This form of heat is known as radiant heat because the heat radiates directly from the source to the food Direct heat is a must when you want to sear the...

Страница 14: ...ood over the ProSear 2 burners before they are fully pre heated because food particles and grease dripping onto a cold ProSear 2 burner can clog the tiny ports and damage the burner For the same reaso...

Страница 15: ...not properly lit like if it were to extinguish in windy conditions During windy conditions it s best to keep the lid closed and to periodically check the burner When the rotisserie is not in use the...

Страница 16: ...moke enhances food raising your culinary skills to the next level Your new grill comes with the new Lynx Smoker Set with handle This oval shaped Lynx Smoker box can be placed anywhere on the grates di...

Страница 17: ...chlorine in the air from swimming pools or the salt from sea air may cause surface rust to appear and even create some pitting if left on the product Here are a few tips to avoid this Regularly wipe...

Страница 18: ...or drippings Every 3 to 6 months remove the burners and inspect the venturi inlet and orifice to ensure that they re free of obstructions Food debris on the inside of the burners can be gently shaken...

Страница 19: ...push in and hold the corresponding control knob Be sure you push in the correct control knob and keep the knob in the OFF position Check the remaining igniters If igniters don t glow proceed with trou...

Страница 20: ...are clean and free from obstructions LP Propane units Is the cylinder almost empty Almost empty cylinders may not have sufficient pressure to run the burners at high heat Have the line pressure check...

Страница 21: ...stay lit when you release the control knob re light it and hold the control knob in for at least 60 seconds to allow the thermocouple to heat up If after holding the control knob in for at least 60 se...

Страница 22: ...nx began with a vision A small group of manufacturing engineers with over a century of collective experience had a dream They dared to take their extensive commercial manufacturing know how and create...

Страница 23: ...the sale or use of its grill products 4 Warranty shall not apply and Lynx is not responsible for damage resulting from misuse abuse alteration of or tampering with the appliance accident hostile envi...

Страница 24: ...ies only to the original location of installation and may not be transferred 3 Warranty is in lieu of all other warranties expressed or implied and all other obligations or liabilities related to the...

Страница 25: ...5 kPa WARNING 1 Always maintain the required clearances from combustible construction as detailed The grill is designed for outdoor use only Never use in a garage building shed breezeway or other enc...

Страница 26: ...and propane Installation Code CSA B149 1 or Propane Storage and Handling Code B149 2 in Canada BEFORE YOU START WARNING IF SHIPMENT ARRIVES DAMAGED IMPORTANT NOTES WHERE S THE WIND When selecting a s...

Страница 27: ...truction combustible au dessous du panneau sup rieur de l appareil 30 cm partir des parois lat rales et 30 cm partir de l arri re Minimum clearance from sides and back of unit to adjacent combustible...

Страница 28: ...28 25 19 00 LDR36T 31 63 19 00 LDR42T 37 63 19 00 SIDE BURNERS MODEL A B C LSB1 12 13 10 63 24 50 LSB2 12 13 10 63 24 50 LSB2PC 24 25 10 63 24 50 LPB 19 00 10 63 22 00 UTILITY DRAWERS MODEL A B C LUD...

Страница 29: ...utout 120V GFI outlet must be located within 6 of the 1 hole 1 2 NPT gas connection CLEARANCE 331 2 34 15 25 ICE MACHINE 3 2 or 2 square holes for manifold connection rear or bottom access 12 min Gril...

Страница 30: ...One way to safely move the grill off of the pallet is by lifting one end of the grill high enough to place a ramp under the wheel and then lift the other end while rolling the grill off of the pallet...

Страница 31: ...e absence of local codes the latest edition of the National Electrical Code ANSI NFPA No 70 or the Canadian Electrical Code CGA 1 6b2005 Use only a Ground Fault Interrupter GFI protected circuit with...

Страница 32: ...llation and all installation parts must conform to local codes with the National Electrical Code ANSI Z223 1 NFPA 70 latest edition and the National Fuel Gas Code ANSI Z223 1 NFPA 54 in the U S and CG...

Страница 33: ...ments The LP cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT and designed for use with a Type 1 system on...

Страница 34: ...r performance at the LOW setting It could be either too high or too low GAS CONNECTIONS continued LP Connections Make sure the LP cylinder valve is fully closed It is possible for the valve to be open...

Страница 35: ...n of the front of the burner before the burner itself becomes weak The factory setting for propane gas is to turn from the very bottom of the adjustment The setting for natural gas is 1 to 1 from the...

Страница 36: ...e Turn the gas supply on and leak test all connections See INDEX Leak Test for further details CART INSTALLATION Shut off the gas supply at the main valve Disconnect all plumbing if already attached f...

Страница 37: ...ALL SEAR CARE USE INSTALLATION 37 L30ASR L30ASFR WIRING SCHEMATICS...

Страница 38: ...38 ALL SEAR CARE USE INSTALLATION L36ASR L36ASFR WIRING SCHEMATICS...

Страница 39: ...ALL SEAR CARE USE INSTALLATION 39 L42ASR L42ASFR WIRING SCHEMATICS...

Страница 40: ...40 ALL SEAR CARE USE INSTALLATION LYNX PROFESSIONAL ALL SEAR GRILL EXPLODED PARTS VIEW...

Страница 41: ...ALL SEAR CARE USE INSTALLATION 41 LYNX PROFESSIONAL ALL SEAR GRILL PARTS LIST...

Страница 42: ...Hr L42AS F R 1 16 000 3 23 000 85 000 Btu Hr MAXIMUM RUNS FOR ALL APPLIANCES ON SUPPLY LINE Run Length 3 4 Pipe in feet Max BTU for all Appliances on line 10 360 000 20 245 000 30 198 000 40 169 000...

Страница 43: ...34 Lighting Manual 12 Lighting Rotisserie Burner 3 11 Lighting Your Grill 3 11 Low Heat Burner Adjustment 34 LP Cylinder Requirements 33 LP Gas 33 M Manual Lighting 12 Match Lighting 12 Maximum Runs f...

Страница 44: ...Lynx Grills Inc 7300 Flores St Downey CA 90242 Service 888 Buy Lynx 888 289 5969 Fax 562 299 6978 www lynxgrills com PN 33526 Rev C 02 2015...

Отзывы: