ALL-SEAR CARE & USE/INSTALLATION
|
33
For freestanding units using natural gas, Lynx strongly
recommends using a quick disconnect kit.
This Quick Disconnect kit, part #LQD, is available
from your dealer.
LP GAS
Grills set up for LP gas come equipped with an LP hose/
regulator assembly for connection to a standard 20 lb.
LP cylinder. (Type 1). All fittings necessary to attach the
assembly to the grill are included.
Permanently plumbed LP connections, such as those in
line with a bulk cylinder, require a 4/11 regulator. (Lynx P/N
30781)
When using the 4/11 regulator you must ensure that it is
set for the proper fuel type. This is done by removing the
regulator cap and gasket and looking at the bottom of the
plunger to see what fuel type is visible. This is the regulator
fuel setting. NAT is for natural gas and LP is for propane
gas. The LP setting can be further identified by the large
diameter disk on the bottom of the plunger. To change
from one gas to the other simply push the plunger to the
side to snap it out of the cap, turn the plunger so it reads
the desired gas type on the bottom, and push the plunger
until it snaps back into place in the cap then replace the
cap into the regulator.
Never connect an unregulated gas line to the grill.
LP Cylinder Requirements
The LP cylinder must be constructed and marked in
accordance with the specifications for LP gas cylinders of
the U.S. Department of Transportation (DOT) and designed
for use with a Type 1 system only.
Cylinders of free
standing grills must
be secured using the
provided cylinder
retention system
to avoid accidental
movement.
When exchanging your cylinder for a refill, exchange only
for a Type 1 20lb cylinder with an over-fill protection device.
Never use a cylinder with a damaged valve.
A dented or rusty LP cylinder may be hazardous and
should be avoided. If in doubt, have it checked by your LP
supplier.
Always check for leaks after every LP cylinder change. (See
INDEX: “Leak Test” for further details.)
Always shut off the LP-gas supply at the cylinder when the
grill is not in use.
Cylinders must be stored outdoors in a well-ventilated area
out of the reach of children. If your grill is stored indoors,
the LP cylinder must be stored outside.
LP cylinder with type 1 valve connection
GAS CONNECTIONS
...
continued
Do not change the regulator/hose assembly or
use any other assembly than the one supplied with
your Lynx grill.
Do not attempt to use a 5LP-A equipped regula-
tor/hose assembly with a standard 510 POL cylin-
der/valve assembly.
Do not store a spare LP-gas cylinder under or near
this appliance.
Never fill the cylinder beyond 80 percent full.
If the information above is not followed exactly, a
fire causing death or serious injury may occur.
WARNING
Содержание All-Sear series
Страница 1: ...ALL SEAR CARE USE INSTALLATION MAKE THE MOST OF YOUR...
Страница 37: ...ALL SEAR CARE USE INSTALLATION 37 L30ASR L30ASFR WIRING SCHEMATICS...
Страница 38: ...38 ALL SEAR CARE USE INSTALLATION L36ASR L36ASFR WIRING SCHEMATICS...
Страница 39: ...ALL SEAR CARE USE INSTALLATION 39 L42ASR L42ASFR WIRING SCHEMATICS...
Страница 40: ...40 ALL SEAR CARE USE INSTALLATION LYNX PROFESSIONAL ALL SEAR GRILL EXPLODED PARTS VIEW...
Страница 41: ...ALL SEAR CARE USE INSTALLATION 41 LYNX PROFESSIONAL ALL SEAR GRILL PARTS LIST...