Страница 2: ......

Страница 3: ...he Luminette Q Laser System 12 3 5 Changing Handpieces 15 3 6 Interlock Warning Screen and LEDs 16 4 CLEANING AND MAINTENANCE 19 4 1 Cleaning 19 4 2 Maintenance Schedule 19 4 3 Maintenance Procedures...

Страница 4: ...A1 3 Available Options and Accessories 22 A1 4 Labelling 23...

Страница 5: ...the Luminette range of IPL laser systems the standard Luminette System the Luminette Advance system and the recently introduced Luminette Q system All of these models look similar from a physical and...

Страница 6: ...ttons Pre set default parameters are included for the different Skin Types all determined through clinical experience The output of the Luminette Q Laser System comprises of passively Q switched laser...

Страница 7: ...onent Users are particularly recommended to read the accompanying Training Manual before using the Luminette Q System for its intended purposes in cosmetic dermatology CAUTION The Luminette Q Laser Sy...

Страница 8: ...detecting equipment should be used The radiation classed as completely invisible may interact with any surface on which it impinges to produce visible light The user is warned that even this light may...

Страница 9: ...chable Handpiece properly connected it does not present the operator with any electrical hazard When Detachable Handpieces are being changed over there are no hazardous voltages on any of the electric...

Страница 10: ......

Страница 11: ...ected to ensure that it has not been unreasonably damaged during transit If the crate has been damaged it is recommended that the supplier is contacted immediately It will then be recommended that pho...

Страница 12: ...Section 4 3 2 of Chapter 4 Cleaning Maintenance Because the internal cooling system requires an air vent a small hole in the pipe of the reservoir filling point to operate properly it is likely that...

Страница 13: ...ressed The key cannot be removed in this position Turn the key switch counter clockwise to turn the Luminette Q System off again at any time Remove the key and store in a safe location when the Lumine...

Страница 14: ...e Q System is shown below 6 Fused Mains Inlet Pulling out the detachable mains lead from this socket removes all power from the Luminette Q System Alternatively the mains lead can unplugged from the w...

Страница 15: ...ividual LEDs comes later 10 Reservoir Filling Point The internal cooling system can be topped up at this point using the pipe provided The pipe is normally fitted with a two position cap In normal use...

Страница 16: ...ns performed at any time will remove the possibility of the emission of light i Turning the key switch counter clockwise to the OFF position ii Pressing the Emergency Stop Button iii Switching off or...

Страница 17: ...ers can be selected and the system can be enabled for treatment This Standby screen displays the handpiece type currently connected to the Luminette Q system in the HP area of the screen As can be see...

Страница 18: ...ing this button increases the rate When the maximum Rate is reached the setting then reverts back to the minimum Rate At this point the User can fire the handpiece by pressing the Pushbutton on the Ha...

Страница 19: ...to remove a Detachable Handpiece and re connect another one To remove a Detachable Handpiece it is necessary to simultaneously press the two buttons on either side of the connector socket whilst at th...

Страница 20: ...le to fire the Flashlamp and the screen will change to INTERLOCK BROKEN Door Interlock Close the Door Press any Key If however there is a more serious Water Flow Water Level or Water Temperature fault...

Страница 21: ...hot Inhibits Flashing If the fault cannot be easily corrected contact Lynton Lasers Ltd or one of its designated agents stating which LED s is are lit If a handpiece reaches the end of it s recommende...

Страница 22: ...18 ________________________________________________________________________________...

Страница 23: ...rial e g Circuit Diagrams Mechanical Design Drawings etc can be made available after consultation with Lynton Lasers Ltd Service Contracts are also available 4 3 1 Topping up the Cooling Water If ther...

Страница 24: ...will light up as well as No 1 Remove the black Reservoir Filler Cap from the Reservoir Filling Point on the back panel of the Luminette Q System and fill up with deionised water using the Filling Bott...

Страница 25: ...able anaesthetic mixture with air or with oxygen or with nitrous oxide NO CLASSIFICATION Classification according to the mode of operation CONTINUOUS OPERATION The Equipment is also classified as PORT...

Страница 26: ...r a suitable pair of glasses or goggles for the Luminette Q Laser System contact Lynton Lasers Ltd A1 2 5 Electrical Parameters Operating Voltage Range 100 125 or 200 264 Volts AC 2 engineer selectabl...

Страница 27: ...ating Plate panel of the label B Panel B Rating Plate panel containing the rated mains voltage with the sign indicating that it is an AC voltage the input mains power the input mains frequency the Ele...

Страница 28: ...t the Luminette Q is a Class 4 Laser System Laser Radiation Starburst Hazard Label Label indicating the requirement for efficient recovery of the Luminette Q System at end of use according to the WEEE...

Страница 29: ...Lynton House Manor Lane Holmes Chapel Cheshire CW4 8AF United Kingdom Telephone 44 0 1477 536977 Fax 44 0 1477 536978 email Info lynton co uk...