![LVO Manufacturing RW1548 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/lvo-manufacturing/rw1548/rw1548_instruction-manual_1953022039.webp)
NAME:
NO.
GA.
SCALE
TOL.
+
-
GND.
LVO MFG. INC.
808 N. 2ND AVE. EAST
ROCK RAPIDS, IA. 51246
PHONE 712-472-3734
1
2
3
4
5
6
7
8
9
10
11
12
13
14
P2
P1
T3
T4
W
R
C
H
T1
T2
24V SCHEMATIC
RW1548-E AUTO FILL & AM FAN
124-1150
SEE FUSE TABLE
C. Woiwood
06-25-07
PAN WASHERS
3Ø POWER DISTRIBUTION BLOCK
FILL
NO
NO
AMBR
NO
NC
RED
ON-OFF
SWITCH
POWER-ON
LIGHT
START
BUTTON
STOP
BUTTON
RINSE
LIGHT
WASH
LIGHT
CLR
SELECTOR
3 PSN WASH
N
O
N
N
N
O
C
C
1
2
3
4
5
6
8
14
11
10
7
9
208 V
230 V
460 V
PRI.
SEC.
3 AMP
3 AMP
2 AMP
12 AMP
12 AMP
12 AMP
13
12
INPUTS
I1 - LOW WTR CUT OFF
I4 - START
I5 - LIGHT WASH
I6 - MEDIUM WASH
I2 - DOOR SWITCH
I3 - STOP
I7 - HEAVY WASH
I8 - AUTO FILL
RELAY OUTPUTS
Q1 - FILL SOLENOID
Q4 - RINSE
Q2 - RED LIGHT
Q3 - WASH
Q5 - AM. FAN
TIMERS
B05 - WASH 03 MIN.
B08 - REST 20 SEC.
B09 - RINSE 60 SEC.
B12 - FAN 60 SEC.
B20 - WASH 05 MIN.
B21 - WASH 07 MIN.
B16 - AUTO FILL 60 SEC
460
230
208
0
X2
XF
24 V
X3
115 V
"C"
1
4
Prog. L24-AF-AD-FN-LW-PF
.1)1
3
3
3
3
3
3
3
3
+
+
+
+
+
+
+
+
+
+
+
P1
P2
P1
P2
P2 TO PRESSURE SWITCH
P1 TO PRESSURE SWITCH
T3 TO RINSE SOLENOID
T4 TO RINSE SOLENOID
W - FROM WASH HIGH LIMIT (Purple)
R - FROM RINSE HIGH LIMIT (Yellow)
C - TO TEMP CONTROL SUPPLY
H - TO TEMP CONTROL SUPPLY
T1 - TO DOOR SWITCH
T2 - TO DOOR SWITCH
FILL - TO FILL SOLENOID
+
24V
C
FUSE TABLE
PUMP
PUMP
FAN
10 HP
5 HP
9 KW
RINSE
9 KW
WASH
WASH
9 KW
RINSE
9 KW
X1
NO
FILL
BUTTON
24VAC
38
SOAP
TO 24VAC
SOAP DISPENSER
Q8 - LWCO
1 - TO LOW WATER FLOAT
4 - TO LOW WATER FLOAT
Temp Control / Gauge
(Rinse) R
NO
SUPPLY
Hot
Com
24VAC
Limit
OUTPUT
H
H
C
or (Wash) W