Trouble Shooting - Gas Machines
(Same as electric model except for the following)
Low wash temperature
1. Check temp control setting.*
2. Check switches, fuses, and breakers that control the burners.
3. Check to be sure electrical power and gas supply have not been interrupted to the burners.
4. Check that all shut-off valves in the gas line and main gas valve are in the "OPEN"
position.
5. Reset ignition control and try again. To reset control:
a. Turn on-off selector switch to the "OFF" position.
b. Wait one minute, turn power switch "ON".
6. If above steps do not light the main burner, call your local gas appliance service technician.
Provide the person working on the machine with the ignition system information
included with this owner's manual.
WARNING: Do not attempt to light the burner manually.
Trouble Shooting - Steam Machines
(Same as electric model except for the following)
Low wash temperature
1. Check temp control setting.*
2. Check boiler pressure.
3. Check to be sure electric signal is being sent to the steam solenoid.
4. Verify that strainer in steam line is open.
5. Check steam solenoid.
* Wash and rinse temp controls are located on the front/side of the machine.
WARNING
Do not set rinse thermostat above the boiling point of water. The boiling point of
water decreases with increased elevation at approximately 2° F per 1000 ft of elevation.