16
6. Check and clean the rinse nozzles with a piece of wire to keep them from plugging up with lime
and scale.
7. Spray down the inside of the machine again.
8. Remove the pump inlet screen (see page 35 for location of screen) and clean it thoroughly in the
sink.
NOTE:
While removing the screen be careful not to allow any debris to fall into the pump
inlet opening.
9. Replace the pump inlet screen and the scrap tray screens.
10. Close the drain and leave the machine empty of water until it is to be used again.
11. (For Pit Models Only) Remove front floor grate(s) and spray pit floor from front toward the rear.
Clean pit drain thoroughly. Water back-up from a clogged drain will cause major burner
damage! DO NOT allow overspray on burner when cleaning. Burner firing problems will