and validate by pressing “
OK
”:
•
rF.un
: unidirectional communication, the digital
thermostat only receives orders from 4 zone programmer.
•
rF.bi
: bidirectional communication with the touch screen
programmer. The digital thermostat returns state and
power consumptions to the programmer.
Then the backlight is stopped and the digits are cycling
showing that the digital thermostat is waiting for a radio
link signal from the Clock to be send (press “
” to cancel
this radio initialization).
When the radio link signal is received, pairing is saved,
backlight lights up it will return to menu selection (rFi).
01
dEG: TYPE OF DEGREES DISPLAYED
Press “
OK
” to enter this parameter. Select with “
+
”
or “
-
“ and validate by pressing “
OK
” :
°C = Celsius
°F = Fahrenheit
04
__._ : CALIBRATION OF THE INTERNAL PROBE
The calibration must be done after 1 day working with
the same setting temperature in accordance with the
following description:
Put a thermometer in the room at 1.5m distance
from the floor (like the thermostat) and check the real
temperature in the room after 1 hour.
When you enter on the calibration parameter the actual
value is displayed.
To enter the value shown on the thermometer, use the
“
-
“ or “
+
” keys to enter the real value. Then, press “
OK
” to
confirm. The hand icon should be displayed, to inform
that a calibration is now made and saved in the memory.
If you need to erase a calibration already made, press
the left navigation key “
”. Then the hand icon must
disappear.
PLEASE NOTE:
Only the heating elements (including slave radiators)
managed by the thermostat must be used during the
calibration process. Do not have a secondary heat source
in the same room for a period of 24 hours before.
05
AF: FROST PROTECTION ON TEMPERATUR
This frost protection temperature used in holiday mode.
Adjustable from 0.5 to 10.0°C. Default value 7.0°C.
08
SRC : SEQUENTIAL CONTROL OF FRONT AND
BACK PANEL
PLEASE NOTE:
This feature is only applicable to double panel radiators.
Press “
OK
” to enter this parameter. Select with “
+
” or “
-
”
and validate by pressing “
OK
”:
NO
: Sequential control function disabled (Front=Back)
YES
: Sequential control function enabled. Heat output is
prioritized to the front panel to maximize radiant heat.
Thus, the "back" heating element will activate if the
temperature is one edge below the set point, acting as a
booster.
PLEASE NOTE:
The rear panel temperature can be considerably lower
than the front panel when this function is enabled.
09
Clr : FACTORY SETTING
Press and hold the “
OK
” key for 10 seconds to reset Set
points temperatures and user parameters in this menu to
factory default settings.
10
SOFTWARE VERSION
xx.x
11
SLA: MASTER - SLAVE SET-UP
Press “
OK
” to enter this parameter. Select with “
+
”
or “
-
“ and validate by pressing “
OK
” :
NO
: radiator control active
YES
: radiator will function as slave radiator and follow
the controls instructions of the master radiator.
12
END: EXIT THE PARAMETER’S MENU
Press the “
OK
” key to exit installation parameter menu
and return to normal operation.