68
GB
GENERAL
INFORMATION
•
Confirm your choice with the “
OK
” key.
•
Use the “
+
” and “
-
“ keys to change the output of the
front panel from 100% (Index 3 in section 2 of the LCD -
Factory setting) to 70% (Index 2 in section 2 of the LCD)
or 55% (Index 1 in section 2 of the LCD) (corresponding to
a maximum surface temperature of 90, 75 or 60°C) and
confirm with the “
OK
” key.
•
The thermostat will return to the “
AUTO
” mode.
•
The display will then show in the right upper corner
(section 2 of the LCD) the index corresponding to the
maximum surface temperature of the front panel.
When considering the permanent use of the radiator at
60°C or 75°C maximum, the following correction factor
should be applied for the output.
INDEX IN
SECTION 2
SURFACE
TEMPERATURE
SINGLE
PANEL
DOUBLE
PANEL
1
60°C max
~ 0.55
~ 0.80
2
75°C max
~ 0.70
~ 0.90
3
90°C max
1
1
E.g.A 1000 Watt single panel programmed for a
maximum surface temperature of 75°C will deliver
maximum 700 Watts. A 1000 Watt double panel
programmed for a maximum surface temperature of
60°C will deliver maximum 800 Watts. These values
should be considered when selecting the number and
type of panels to cover the calculated heat losses.
KEY LOCK FUNCTION
Use the Key Lock function to prevent any changes to
your settings (in a child’s room, public area … etc)
•
To activate the Key Lock function, first press and
maintain the “
OK
” key and then simultaneously on
the left “
” navigation key.
•
The key icon will be displayed on the screen.
•
Repeat the same procedure to unlock the keyboard.
This function is available in all operating modes.
WINDOW OPEN FUNCTION
The radiator is equipped with a “window open” function.
This function will switch the radiator from any active
mode to “Frost Protection” mode when an open window
is detected (room temperature drops by more than 5°C
in less than 30 minutes). The window open icon will start to
blink and continue to blink as long as the function is active.
To return to the previous or automatic mode push the
“
OK
” key twice. If no manual intervention has been
detected, the radiator will check automatically, after 30
mins, if the room temperature has increased (window
has been closed) and if so, return automatically to the
previous or automatic operation mode.
BEHAVIOUR INDICATOR
This is the bar at the bottom of the LCD display that
gives a visual indication of how much energy the
current temperature setting is i.e.
red =high
orange = medium
green = low energy comsumption
As you increase the temperature setting, the behavior
indicator "bar" will increase length. The opposite applies
when decreasing the temperature setting.
4. PARAMETER MENU
Your thermostat has a parameter menu. In order to
enter this menu, press and hold the “
OK
” key for 5
seconds. Then the parameter menu will appear and the
first menu screen will displayed.
Parameters can be selected using the left “
” and
right “
” navigation keys Once the parameter is
chosen, toggle the value with the “
OK
” key, modify it
with the “
+
” or “
-
“ keys and confirm your adjustment
with the “
OK
” key.
To exit the parameter menu, choose the parameter
“
END
” and press “
OK
”.
DEFAULT VALUE & OTHER POSSIBILITIES
00
rF i: WIRELESS RADIO INITIALIZATION (PAIRING)
Press “
OK
” to enter this initialization sequence.
Select with “
+