GENERAL
INFORMATION
•
CONNECTED TO A CENTRAL CLOCK BY WIRE (Picture 4)
AUTOMATIC MODE
•
Comfort mode/temperature is active. The , in
section 8 of the LCD display, is constantly displayed.
•
Reduced mode/temperature is active. The , in
section 8 of the LCD display, blinks.
•
WIRELESS LVI RF CENTRAL PROGRAMMER
AUTOMATIC MODE
•
Comfort mode/temperature is active. The , in
section 8 of the LCD display, is constantly displayed.
•
Reduced mode/temperature is active. The , in
section 8 of the LCD display, is constantly displayed.
•
Frost protection mode/temperature is active. The ,
in section 8 of the LCD display, blinks.
•
The radiator is switched off. The , in section 8 of the
LCD display, blinks and "OFF" is constantly displayed.
The icon is active when wireless programmer and
radiator thermostat exchange information (e.g. order to
change the operating mode).
RADIATORS CONNECTED IN A
MASTER – SLAVE SETUP
•
When several radiators are installed in a room, one of
them can be selected as a “master”, while the others
could function as “slaves”. The slaves will follow the
heating instructions from the master radiator.
•
This set-up requires appropriate wiring (picture 4).
Note! All radiators in a master/slave-group must be
connected to the same phase on pin 1.
•
Check the parameter menu (11 SLA) to configure the
radiator as a slave radiator.
•
Older LVI products must not be connected as
slave/master with this product.
•
A maximum number of 10 slaves can be connected.
RADIATORS CONNECTED TO AN
EXTERNAL THERMOSTAT OR BMS
• When using an external thermostat which controls the
room temperature, set the comfort temperature t0
30°C and the reduced temperature to to 5°C. Connect
the radiator according to picture 4 in such way that pin 3 is
open when the radiator should emit heat and connected to
Neutral when the radiator should not emit heat.
NOTE:
Radiators must be connected as masters in this case.
Each and every radiator must also be defined as master in the
parameter menu.
NOTE:
Do not connect an external thermostat directly to pin
1 or 2 as this will shorten the life time of the radiator.
OTHER FUNCTIONS
TIMER FUNCTION
The timer function allows you to override the
programmed settings (temperature and operating mode)
for a chosen period of time, starting from the moment
that the timer function is activated.
•
Move the frame cursor to the timer icon.
•
Confirm your choice with the “
OK
” key.
•
Set the desired temperature using the“
+
” and “
-
“ keys
and confirm with the “
OK
” key.
•
Adjust the period using the “
+
” and “
-
“ keys between 1
hour and 44 days. Confirm with the “
OK
” key.
•
The icon will start to blink and the desired temperature is
displayed until the end of the set period.
•
If you want to stop the timer before the end of the set
period, select another mode using the “
” key and confirm
with the “
OK
” key.
FRONT PANEL TEMPERATURE LIMITATION
The power setting can be used to limit the output of the
heating element in the front panel and as a consequence
the surface temperature of the front panel.
•
Move the frame cursor to the power icon.