1. GENERAL INFORMATION
•
This appliance is a sealed electric radiator designed
for fixed wall-mounted installation.
•
This appliance conforms to the standards EN 60 335-1
and EN 60 335-2-30.
•
This appliance is insulation class 1, has a electrical
protection level IP 21 when used with the standard
connection box and a electrical protection level IP 44
when used with the standard connection box AND the
splash proof cover (to be ordered separately).
•
This appliance complies with European Directive
2004/108/EC (CE Marking on all appliances).
•
The product is supplied with wall brackets and screws.
•
The YALI D C is supplied complete with a connection cable
equipped with a 5-pole connector and connection box.
•
The YALI D P (where available) is supplied complete with a
connection cable equipped with a 2 -pin Schuko plug.
PLEASE NOTE:
The YALI D P has limited functionality due to only being
equipped with a 2-pin Schuko plug, therefore it will
not be possible to have a wired connection to a central
programmer, external clock, BMS, or connected in a
master/slave setup.
2. INSTALLATION
POSITIONING
•
The radiator must be positioned horizontally in
order for it to function correctly.
•
The radiator must be positioned according to the
applicable standards. The minimum distances as
specified in picture 1 should be carefully observed
(the recommended distance is from the floor is 100 mm).
•
The radiator may be positioned “outside” zone 2
with the standard connection box and in zone 2 if the
connection box is equipped with a splash proof cover
(picture 2), insofar as no operating controls (button,
switch, etc …) are in reach of persons in the bath or
under the shower.
•
The radiator must be fixed to the wall using the
wall brackets supplied.
•
The radiator must not be located underneath an
electrical socket.
FIXING
•
Insert the safety clips in the wall brackets as shown
in picture 3c.
•
Mark out the distance between the brackets and the
positions for the screw holes as shown in the table in
picture 3a (single panel) or 3b (double panel).
•
For the correct installation of radiators it is essential that
the fixing of the radiator is carried out in such a way that
it is suitable for intended use AND predictable misuse. A
number of elements need to be taken into consideration
including the fixing method used to secure the radiator
to the wall, the type and condition of the wall itself,
and any additional potential forces or weights, prior to
finalising installation.
•
The fixing materials provided are only intended for
installation on walls made of solid wood, bricks, concrete
or on timber-frame stud walls where the fixing is into the
timber. All walls being considered should have no more
than a maximum of 3 mm wall finishing. For walls made
of other materials, for example hollow bricks; please
consult your installer and/or specialist supplier.
In all cases it is strongly recommended that a suitably
qualified professional installer or similar tradesperson
carries out the installation.
CONNECTION
•
Installation must comply with local or national electrical
regulations. The radiator should be connected by a
suitable and qualified electrician.
•
Please refer to the wiring diagram in picture 4 for the
connection of the radiator (Excludes YALI C P model).
•
The radiator must be connected to the electrical supply
using the supply cable fitted to the unit.
•
If the radiator is installed in a bathroom or shower room,
it must be protected with a residual current device (RCD)
with a rated residual current not exceeding 30 mA.
•
The radiator is equipped with a non-resettable overheat
GB
GENERAL
INFORMATION
|
64