![Luxul XMS-1008P Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/luxul/xms-1008p/xms-1008p_user-manual_1952784019.webp)
luxul.com | 357 South 670 West | Suite 160 | Lindon, UT 84042 | p: 801-822-5450 | f: 801-822-5460
User Guide
19
5.5.1 POE Confi guration
This page allows you to control port power distribution, enabling a specifi c port to
provide power. The confi guration options are displayed below:
Field
Description
Power
Management
Modes
There are three power management modes:
1) Powered Device Based Priority
2) Static Allocation
3) Dynamic allocation.
Powered Device Based Priority:
the power allocation is
automatically determined by the XMS-1008P according to the class
of the Powered Device. For instance, if class 0 or 4 is detected, then
the allocated power it receives is the actual power consumed by the
Powered Device. If class 1 is detected, then the allocated power it
will receive is 4W. If class 2 is detected, the allocated power it will
receive is 7W. If class 3 is detected, the allocated power it will receive
is 15.4W. If the consumed power of the Powered Device exceeds the
port power limit pre-defi ned by the Powered Device’s class, then the
port will terminate power allocation to it and attempt re-initialize it
in 5 seconds.
Static Allocation:
Power allocation is determined by the manually
confi gured value per port. If the consumed power of a Powered
Device exceeds the manually confi gured value on the port, the port
will terminate power allocation and attempt to re-initialize.
Dynamic Allocation:
Power allocation is determined by the
consumed power of the Powered Device. If the consumed power of
the Powered Device exceeds 15.4W, the port will terminate power
allocation and attempt to re-initialize.