background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FEATURES AND SPECIFICATIONS 

                                 Note: Always check appliance label for correct information 

 

The Luxor Riviera 66 is a direct vent gas 
appliance utilizing an inclined vent for superior 
installation flexibility.  It enables either horizontal 
or vertical vent installation without laboring to 
convert over a dual type unit or having to 
purchase a dedicated vent configuration.

 

MODEL: RIVIERA-66

   

 

                             

Natural Gas

 

 

 

 

Manifold Pressure 

 

 

                             3.5in w.c. 

 

 

 

Min. Supply pressure 

 

 

                             5.0in w.c. 

 

 

                                                               

Max Supply pressure 

 

 

                             11in w.c. 

 

 

 

Orifice size (x2)   

 

 

                             #42  

 

 

 

  

Nominal input rating 

 

 

 

 

46,000 BTU/hr   

High altitude (US) 

 

 

 

 

0-2000ft / 0-610m 

High altitude (Canada) 

 

 

 

 

0-4500ft / 0-1370m 

Primary Air Opening 
Electrical Rating   

 

 

 

 

115 volts 0.7 amp 60hz 

Circulating fan (optional)   

 

 

 

Variable Speed 

Vent System 

 

 

 

 

 

Direct Vent 

Glass 

 

 

 

 

 

 

Ceramic 

 
HIGH ALTITUDE INSTALLATION 
When installing this appliance beyond 2000ft (610M) above sea level, the appliance must be properly derated and  
Installed according to local codes, in absence of local codes, with the current National Fuel Gas Code, ANSI 
Z223.1/NFPA 54, in the US or Installation Code, CAN.CGA-B149, in Canada. 
 
HIGH ALTITUDE INPUT DE-RATING 
0-2000ft (0-610M):  46,000 BTU/hr (13.48kW)          
2000ft (610M) and above:  46,000 BTU/hr (13.48kW) less 4% per 1000 ft. (305M) 
 
Please Note: Only products supplied by the manufacturer may be used in the installation of this appliance. 

 

Содержание Riviera-66

Страница 1: ...nual for future reference Do not store or use gasoline or other Flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any applianc...

Страница 2: ...omponents Page 10 Vent Installation Page 11 Vertical Venting Page 12 Horizontal Venting Page 13 Exterior Vent Clearances Page 14 Installation Planning Page 15 Installing Non Combustible Panels Page 16...

Страница 3: ...uld have at least on fire extinguisher An approved Class A B C extinguisher should be mounted on the wall near an exit and close to the application but not so close that accessibility to the extinguis...

Страница 4: ...s Nothing should ever be placed on or near the surface of the fireplace including the top of the unit Clothing or other flammable material should not be placed on or near the appliance Make certain th...

Страница 5: ...e US 0 2000ft 0 610m High altitude Canada 0 4500ft 0 1370m Primary Air Opening Electrical Rating 115 volts 0 7 amp 60hz Circulating fan optional Variable Speed Vent System Direct Vent Glass Ceramic HI...

Страница 6: ...rtical framing with appliance Riv66 framing with Non comp panels and wall thimble SHEET 1 OF 1 UNLESS OTHERWISE SPECIFIED SCALE 1 48 REV DWG NO A SIZE TITLE NAME DATE COMMENTS DRAWN FINISH MA TERIA L...

Страница 7: ...llustration Caution any finish like stains or clear coatings must be of a high heat design to prevent discolouration Placement of Appliance Non Combustible Panels The factory supplies two non combusti...

Страница 8: ...e access to the gas compartment becomes limited A grounded 117volt AC line must be supplied to the appliance and wired into the electrical box which is fixed to the right hand side of the appliance Th...

Страница 9: ...able performance WARNING This gas appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Side Wall Co Axial termination 58DVA HC Vertical Co Axial Terminatio...

Страница 10: ...ured by three screws High temperature sealant is recommended at the connection start of the venting on the appliance end Use high temperature silicone or Mill Pac If for any reason the venting must be...

Страница 11: ...ations can be either horizontal or vertical in any combination that does not exceed the four elbow limit Vertical Flexible Chimney of any kind is prohibited in the installation of this appliance When...

Страница 12: ...n that does not exceed the four elbow limit All horizontal vent termination installations must install the 6in by 16in high heat plate on the wall face directly above the termination cap Failure to in...

Страница 13: ...9 Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance K 1 83m 3 above if within 10 horizontally Clearance to mechanical air supply inlet L 2 13...

Страница 14: ...place The line must be properly sized and fitted according to the installation codes Upstream of the appliance supply connection the fitter shall provide an easily accessible manual shut off valve The...

Страница 15: ...x17 25 panel is for installation beneath the appliance In addition a single 14 x 3 must be installed at the top of the wall opening when venting is routed horizontally through a side wall Cleanface Su...

Страница 16: ...for supporting the cover grille to be installed on completion A Power drill with Hex Nut driver should be used to attach surround as shown in Figure 2 Pre punched holes are provided Once the top has...

Страница 17: ...o secure it in place The Non combustible board can be fastened with standard drywall screws through the recessed holes provided when the appliance is ready to close in Figure 5 Figure 6 Install metal...

Страница 18: ...is appliance Do not use substitute materials Replacement of the panel should only be carried out by a licensed qualified service person Door Removal and Re Installation Instructions Window Re Installa...

Страница 19: ...rical Schematic This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadi...

Страница 20: ...will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier Lighting Instructions Operating Instructions WARNING If you do not follow these i...

Страница 21: ...g s control and is not covered under warranty 1 Clean the glass regularly as soon as you notice the buildup white film If the film is left for a longer period of time build up will bake on Once baked...

Страница 22: ...n and run two conductor thermostat wires to the heater s lower right hand corner close to the gas supply line Note The thermostat or wall switch MUST be rated for electronic Minimize splicing in all w...

Страница 23: ...on glass Adjustment None Close damper Open damper Flame Quality Adjustment Access to this feature is done through the top of the burner cover by removing the two fasteners from the rectangular metal c...

Страница 24: ...ifice Danna Controls LPPO Main Burner Orifice Liquid Propane MB042LP Main Burner Orifice Natural Gas MBO42NG NON COMBUSTABILE COMPONENTS Front Panel 43 X 34 w Base Panel for under Riviera 42 FB001 Thr...

Страница 25: ...ponent Servicing Burner Removal First step is to remove the door Assembly refer to page 17 Once the door has been removed remove any decorative media that may be on the burner trays The rear baffle pa...

Страница 26: ...with respect to the Luxor Limited Lifetime Warranty CFHMfg may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the whol...

Отзывы: