SAFETY AND FUNCTIONAL CHECK 

Carried out by the manufacturer according to the following data:

The following elements are present:

 Technical nameplate on the product (hydraulic power unit)

 Instructions for use

 Max. load capacity (2 500 kg)

 Raise «UP», lower «DN» on the wired control unit.

 CE Identification

Controlled operation and safety:

Pressure relief valve set at 180 bars

Check:

 No-load function test over a complete cycle

 Operation of the mechanical safety devices and the emergency stop button

 Controls automatically return to the initial position 

 No damage to the cylinders, the power supply cable, and the wired remote control cable

 Tight fastening of all bearing screws

 Condition of the hydraulic hoses (all connections are tightly fastened and sealed).

 Full cycle load operation

Serial No:_________________

Date:______________________

Name:______________________

The builder: Yantai Tonghe Precision Industry Co., Ltd.

Address : No. 151, Middle Road, Xili Industrial Park, Zhifu District Yantai City

Zip code: 264004

Tel: 0535 6736715

Fax: 0535 6855506

Email: [email protected]

Web: www.ytthjg.com  &   www.yt-tonghe.com

Flat ramp

Содержание 3154020062184

Страница 1: ...73502 V6 19 05 2021 EN 1 24 QUICK LIFT L520E Translation of the original notice...

Страница 2: ...g Safety in case of mechanical fall YES 2 positions Safety in case of hydraulic hose rupture YES Electrical installation 220 V 50Hz Power 0 75 kW Hydraulic tank capacity 4L Noise level 70dA Ascent and...

Страница 3: ...al safety devices and the emergency stop button Controls automatically return to the initial position No damage to the cylinders the power supply cable and the wired remote control cable Tight fasteni...

Страница 4: ...te of Conformity EC Machinery Directive 2006 42 EC ROHS2 directive 2011 65 EU and its amendment 2015 863 Report No EN1493 2010 EN50581 2012 Control body TF C 1212 18 155 04 5A NGBEC1802310202 Organism...

Страница 5: ...ification of the product Insufficient maintenance INTENDED INTENDED USE The QUICK LIFT is designed for the repair of passenger vehicles It allows vehicles to be lifted safely The maximum load of the Q...

Страница 6: ...is not recommended to work next to a heat source The QUICK LIFT was not designed for use in a spray booth It is forbidden to use spare parts other than original parts certified by the manufacturer Ma...

Страница 7: ...c hoses i The ramps are very similar but they are not interchangeable The mechanical safety must always be on the outside and the ramps pointing in the same direction STOP UP DN Transport handles Cast...

Страница 8: ...onnections Step 3 The tank of the hydraulic unit is empty It must be filled with hydraulic oil or automatic transmission fluid before starting operation Approved fluids are general purpose hydraulic o...

Страница 9: ...ty area In order to guarantee the operator s safety the control box must be located at a distance that allows an escape route in case of emergency INSTALLATION Once the tool has been removed from its...

Страница 10: ...ther and therefore in the passage of the locking bars on the blocks This is nor mal On load the ramps will be synchronized and the offset will be corrected Pressing DN down will lower the ramps until...

Страница 11: ...ng a vehicle with QUICK LIFT you should be aware of this Case 1 Do not deploy both ramps at full height when unladen One way to become familiar with the use of your QUICK LIFT is to raise and lower th...

Страница 12: ...trol When the vehicle leaves the ground do not stop the deployment of the ramps until the first locking position is reached Never leave a vehicle elevated unless both safety bars are in the locked pos...

Страница 13: ...the locking bars so that the 2 cams rest on the ground Press DN down until the ramps return to the initial position Please make sure that the cams slide smoothly through each passage of the locking bl...

Страница 14: ...ress DN on the remote control to make sure that there is no more pressure in the circuit and that both ramps are on the ground MAINTENANCE TABLE Maintenance intervals Task Remarks Monthly Check clean...

Страница 15: ...system is under pressure Wear protective equipment goggles gloves and safety shoes when handling the Quick Lift If hydraulic fluid comes into contact with the eyes enters the bloodstream or is swal l...

Страница 16: ...ce parts are broken bent or cracked START UP The QUICK LIFT must be disposed of in accordance with the current environmental and disposal guidelines of the country in which it is located WARRANTY COND...

Страница 17: ...17 QUICK LIFT L520E EN OPTIONS SKIDS FOR SUV r f 065017 A A A A x2 OPTIONS EXTENSIONS r f 066328 A A A A A A x2...

Страница 18: ...4M Hydraulic Tube 5 Supporting Palm for SUV 4pcs optional Quick Lift components List 1 Lifting Frame 2 pcs 2 Rubber Plate 4pcs 3 Power Unit AC 220V 50Hz DC12V battery holder optional 4 4M Hydraulic Tu...

Страница 19: ...t Breaker 10A250V M N L L AC220 PE JAT Emergency Stop HYDRAULIC CIRCUIT M Filter Electric machinery Overflow valve Two position two way electromagnetic reversing valve Single spring valve Synchronizin...

Страница 20: ...ng stops The emergency stop button is functional Condition of the load bearing construction mechanical struc ture Condition of the locking blocks height 1 and height 2 Condition of locking bars cams a...