22
0698-701 Relay module - 04/2021
en
3. Maintenance and servicing
3.1 Changing the fuse in the relay module/power supply unit
!
DANGER
Live mains connection!
Electric shock can kill you.
►
Before dismantling remove the plug.
!
DANGER
Danger of explosion from short circuit!
Combustion hazard.
Blast wave: Flying parts can kill you.
►
Only use the types of fuses listed below.
As the blowing of a fuse generally precedes a fault, have the unit checked by an electrical specialist before
changing a fuse.
The units are adequately protected when 5 x 20 mm IEC 127 fine wire fuses are used:
RM10
RM10
RM30
NG10
NG10
230 V
120 V
400/230 V
230 V
120 V
Mains connection F3 40 mA (T)
80 mA (T)
40 mA (T)
40 mA (T)
80 mA (T)
Output pump F2
8 A time-lag (T) 8 A time-lag (T) Internal fuse 0.5
A (T)
Fuse protection
on the mains side
with max. 16 A
-
-
Output valve F1
0.5 A (T)
0.5 A (T)
0.5 A (T)
-
-