13. Insert screws suitable for
the base (max. 5 mm thread
diameter, not included in the
scope of supply).
14. Mount the intermediate plate
on a firm and level base.
15. Insert the lateral sealing
covers including the flange
nuts. Make sure that there are
two different versions.
16. Carefully mount the relay
module/power supply unit
in the advised position and
tighten up the screws.
17. Connect the plug of the relay
module/power supply unit
to the male header of the
operating unit.
18. Replace the operating unit
onto the relay module/power
supply unit and mount the
caps.
19. Connect the plug with the
circuit board of the pulse
converter (or with the ribbon
cable of the protection cap).
20. Attach the pulse converter /
protection cap onto the flow
meter and mount the caps.
21. Connect the operating
unit and pulse converter /
protection cap using the data
line.
Fig. 11c - Separate installation of
relay module/power supply unit
and operating unit
Fig. 11d - Separate installation of
relay module/power supply unit and
operating unit