27
0698-701 Relay module - 04/2021
en
Operating mode Fault report
Cause
Remedy
Flow monitoring
On
Flow rate too low
• Pump damaged
• Check pump
• Line strainer blocked • Clean strainer
• Hose line kinked
• Check hose line
• Solenoid valve
damaged
• Check solenoid valve
Flow monitoring
On
Flow rate too high
• Flow control valve
misaligned
•
Adjust the flow control valve
Volume preset
No pulses
• Air in the piping
system/dry running
• Prevent air pockets in
connecting lines, use a solid
hose system
• Pump is not operating • Check pump
• Line strainer blocked • Clean strainer
• Time required to
fill the connecting
lines exceeds the set
monitoring time
• Increase monitoring time
• Hose line kinked
• Check hose line
• Solenoid valve
damaged
• Check solenoid valve
• The connection
between the modules
is interrupted
• Check bus line
•
Basic flow meter
damaged
•
Check basic flow meter
• Fuse in relay module
defective
• Check fuses
• Magnet or sensor
in basic flow meter
damaged
•
Check basic flow meter
Volume preset /
Leakage alarm
On
Leakage in system
• Pipe or connections
not properly sealed
• Check the pipe and
connections
• Solenoid valve does
not close properly
• Check solenoid valve