Troubleshooting
Type of fault
50
© Lutz-Jesco GmbH 2014
BA-10103-02-V01
Stepper Motor-driven Diaphragm Dosing Pump
MEMDOS SMART LK
Operating instructions
Possible cause
Remedy
Dry the valves
Dampen the dosing head and the
valves
Vent the dosing head.
Air in the suction line with
simultaneous pressure on the
discharge valve
Vent the dosing head or the lines.
Tab. 43: Type of fault: Dosing pump does not prime
13.1.3 Delivery rate varies
Possible cause
Remedy
Valve leaking or blocked
Clean the valve and vent the
dosing pump.
Tighten the screw connections.
Valve damaged (e.g. valve
balls)
Remove the damaged parts or
install a new valve.
Suction line is leaking
Seal the leak locations or replace
the parts.
Suction line is blocked (e.g.
screen in foot valve)
Clean the suction line
Viscosity too high
Set Slow Motion 1
Possibly reduce the concentration
of the dosing medium or increase
the temperature.
Install spring-loaded valves.
Increase the pipe diameter.
The dosing pump's electrical
data does not match that of
the mains supply
Check the electrical installation.
Suction side pressure too high
(pump siphoning)
Install a back-pressure valve in
the pressure line.
Pressure peaks due to
acceleration with long suction
lines
Install a suction pressure
regulator.
Imprecise dosing due to
changeable positive and
negative suction heads.
Install a suction pressure
regulator.
System back pressure too
high (measured at discharge
connection of dosing pump)
Clean blocked injection nozzle.
Install pulsation dampeners to
reduce pressure peaks if pipes
are too long.
Check function of safety valves.
Tab. 44: Type of fault: Delivery rate varies
13.1.4 No stroke movement observed
Possible cause
Remedy
Diaphragm return spring
broken.
Contact the manufacturer.
Current supply interrupted
Reconnect the current supply
The dosing pump's electrical
data does not match that of
the mains supply
Check the electrical installation.
Pressure peaks due to
acceleration with long suction
lines
Install a suction pressure
regulator.
System back pressure too
high (measured at discharge
connection of dosing pump)
Clean blocked injection nozzle.
Install pulsation dampeners to
reduce pressure peaks if pipes
are too long.
Check function of safety valves.
Tab. 45: Type of fault: No stroke movement observed
13.1.5 Dosing pump delivery rate too high
Possible cause
Remedy
Suction side pressure too high
(pump siphoning)
Install a back-pressure valve in
the pressure line.
Pressure peaks due to
acceleration with long suction
lines
Install a suction pressure
regulator.
Tab. 46: Type of fault: Dosing pump delivery rate too high
13.1.6 Diaphragm is torn or tears too often
Possible cause
Remedy
Shut-off valves closed
Open the shut-off valves Inspect
the dosing pump for possible
damage.
Pressure peaks due to
acceleration with long suction
lines
Install a suction pressure
regulator.
The materials are not suitable
for the dosing medium being
used
Check the resistance of the
materials.
Diaphragm not screwed up to
the end stop on the dia-
phragm rod
Screw a new diaphragm up to the
end stop.
Tab. 47: Type of fault: Diaphragm is torn or tears too often