Stepper Motor-driven Diaphragm Dosing Pump
MEMDOS SMART LK
Operating instructions
11.1.3 Calibrating the dosing pump
In dependence on the dosing medium you are using and the existing
delivery pressure, you must match the theoretical delivery capacity with
that which is actually measured. You use the
Calibration
function to do
this.
Precondition for action:
The plant sections on the discharge side of the dosing pump have
been installed correctly and are ready for operation.
Perform the following working steps:
1.
Fill the metering container with the dosing medium.
2.
Hold the end of the dosing pump's suction line in the metering
container.
3.
Vent the dosing pump (see chapter 11.1.1 „Venting the dosing
pump“ on page 40).
4.
Press
Menu
.
5.
Use the or key to choose the
Calibration
menu item and press
OK
.
The dosing pump displays menu 5
Calibration
.
Calibration
Capacity 100 %
Menu
5
Start
-
+
Fig. 47: Menu 5 Calibration
6.
Use the
+
and
-
keys to set the percentage value of the delivery
capacity with which you want to carry out calibration. Setting range
10 % – 100 %.
7.
Press
Start
.
The dosing pump starts delivery and displays the number of
executed strokes.
8.
Press
Finish
as soon as you have achieved a measurable value in
the metering container.
The dosing pump stops and displays the theoretical value of the
delivery rate in ml.
Calibration
Capacity 5.67ml
Menu
5.3
OK
-
+
Factory setup +0.0%
Fig. 48: Menu 5.3 Calibration
9.
Read off the actual delivery rate from the metering container and use
the
+
and
-
keys to correct the displayed delivery capacity.
Adjustment range: -50 % – +50 %
10.
Press
OK
.
The dosing pump is calibrated.
11.2 Operating modes
The MEMDOS SMART LK dosing pump offers the following operating
modes:
Manual operation
- Manual setting of the delivery capacity,
Pulse input
- Controlling the stroke frequency and number of
strokes in dependence on the number of pulses and the pulse
spacing,
11.2.1 Manual mode
CAUTION
Danger of automatic start up!
If the dosing pump is in manual mode with a specifi ed stroke
frequency, it retains the stroke frequency even after you disconnect if
from the mains and then reconnect it. This means that dosing medium
can escape. Depending on the type and hazardousness of the dosing
medium, this can result in injury.
Stop the dosing pump before disconnecting it from the mains
supply.
Ensure that the dosing pump has been installed correctly before
connecting it to the mains supply.
11.2.1.1 Selecting the operating mode
1.
Press
Menu
.
2.
Use the or key to choose the
Operating mode
menu item and
press
OK
.
3.
Use the or key to choose the
Manual mode
menu item and
press
OK
.
The dosing pump displays the start screen of
Manual mode
mode.
Manual mode
Menu
Stop
-
+
Liter
h
0%
0.00
Fig. 49: Start screen of Manual operation
11.2.1.2 Starting the dosing pump
1.
Press the
+
key to increase the stroke frequency by 0.1 %.
The dosing pumps starts dosing immediately. The system
automatically calculates the resulting delivery capacity and displays
it.
2.
Use the
+
and
-
keys to set the desired stroke frequency.
Dosing pump has started.