Technical specifi cations
Operating conditions and limits
14
© Lutz-Jesco GmbH 2014
BA-10103-02-V01
Stepper Motor-driven Diaphragm Dosing Pump
MEMDOS SMART LK
Operating instructions
5 Technical specifi cations
5.1 Delivery capacity data
Please note that some of this data only represents guide values. The actual capacity of a dosing pump depends on various factors. For approximate
values of the delivery capacity at different pressures, refer to chapter 15 „Delivery characteristic curves“ on page 53.
Information
Value
MEMDOS SMART LK Size
5
10
15
20
Delivery capacity at max. back pressure
l/h
5.3
10.8
14.2
19.2
ml/stroke
0.59
1.20
1.58
2.13
Max. delivery pressure
bar
15
9
5
4
Delivery capacity at average back pressure
l/h
6
11.3
14.7
19.7
ml/stroke
0.67
1.26
1.63
2.19
Average delivery pressure
bar
8
5
3
2
Max. stroke frequency
min
-1
150
Suction height for non-gassing media (with a fi lled suction
line)
mWS
3
Tab. 7: Output data
5.2 Operating conditions and limits
Information
Value
MEMDOS SMART LK Size
5 – 20
Permitted ambient temperature
°C
5 – 45 (with PVC parts 5 – 40)*
Relative humidity
%
Max. 90
Max. sound pressure level
dB(A)
51 – 56
Max. supply pressure
mbar
800
Viscosity limits
mPa s
300** / 1000***
Adjustable dosing range
%
0 – 100
Tab. 8: Operating conditions and limits
* Use of the dosing pump at ambient temperatures below 5°C must be checked individually. In those cases please contact the manufacturer.
** With a viscosity of ~300 mPa s and above, you must use spring-loaded valves.
*** If the viscosity is above 1000 mPa s, this must be checked individually