background image

Appropriate and intended use

Notes to Product warranty

7

© Lutz-Jesco GmbH 2014
Subject to technical changes
140410

Stepper Motor-driven Diaphragm Dosing Pump 

MEMDOS SMART LB

Operating Instructions

BA-10100-02-V02

3  Appropriate and intended use

3.1  Notes to Product warranty

Any non-designated use of the product can compromise its function or 
intended protection. This leads to invalidation of any warranty claims!

Please note that liability is on the side of the user in the following cases:

The dosing pump is operated in a manner which is not consistent 
with these operating instructions, particularly the safety and 
handling instructions and the chapter entitled “Appropriate and 
intended use“.

If people operate the product who are not adequately qualified to 
carry out their respective activities,

No original spare parts or accessories of Lutz-Jesco GmbH are used,

Unauthorised changes are made to the device by the user,

The user uses different dosing media than those indicated in  the 
order,

The user does not use dosing media under the conditions agreed 
with the manufacturer such as modified concentration, density, 
temperature, contamination, etc.

3.2  Intended purpose

The MEMDOS SMART LB dosing pump is intended for the following 
purpose: the conveying and dosing of liquids.

3.3  Device revision

This operating manual applies to the following devices:

3.4  Principles

Before delivery, the manufacturer inspected the dosing pump and 
operated it under specific conditions (with a specific dosing medium 
with a specific density and temperature, with specific pipe dimen-
sions, etc.) Since these conditions vary at every installation location, 
you must calibrate the dosing pump after delivery. For information 
on the calibration procedure refer to Chapter ”Calibrating the dosing 
pump“ (see page 31). F
or details on the approximate values and the 
capacity of the dosing pump, refer to the chapter entitled ”Delivery 
characteristic curves“ (see page 40).

Information on the usage and environment (see "Technical specifica-
tions" on page 12)
 applies.

Any restrictions regarding the viscosity, temperature and density of 
dosing media must be followed. You must only use dosing media at 
temperatures above freezing point or below the boiling point of the 
respective medium.

The materials of the dosing pump and hydraulic parts of the system 
must be suitable for the dosing medium that is used. In this connec-
tion, note that the resistance of these components can change in 
dependence on the temperature of the media and the operating 
pressure.

The dosing pump is not intended for outdoor use unless appropriate 
protective measures have been taken.

Avoid leaks of liquids and dust into the casing and avoid direct expo-
sure to sunlight.

You must never operate dosing pumps in a potentially explosive 
atmosphere if they do not have corresponding nameplates or an 
appropriate EC Declaration of Conformity for potentially explosive 
atmospheres.

3.5  Prohibited dosing media

The  dosing pump must not be used for these media and substances:

Gaseous media,

radioactive media,

solid substances,

combustible media,

all other media that are not suitable for delivery using this dosing 
pump.

3.6  Foreseeable misuse

Below, there is information about the applications of the dosing pump or 
associated equipment that are not considered to be intended use. This 
chapter is intended to allow you to detect possible misuse in advance 
and to avoid it.

Foreseeable misuse is assigned to the individual stages of the product 
lifetime:

3.6.1 Incorrect assembly

Unstable or unsuitable bracket

Dosing pump bolted wrongly or loosely

3.6.2 Incorrect hydraulic installation

Suction and pressure lines dimensioned incorrectly

Unsuitable connection of the pipes due to wrong material or unsuit-
able connections.

Suction and pressure lines mixed-up

Damage to threads due to them being tightened too much

Bending of pipelines

No free return flow of the pressure relief valve

Excessive demand due to the pressure differences between the 
suction and discharge valves

Device

Month / year of manufacture

MEMDOS SMART LB

04/2014 onwards

Table 3-1:

Device revision

Information on the suitability of materials combined with 
different dosing media can be found in the Chemical Resist-
ance List of Lutz-Jesco GmbH.
The information in this resistance list is based on information 
from the material manufacturers and on expertise obtained 
by Lutz-Jesco from handling the materials.
As the durability of the materials depends on many factors, 
this list only constitutes initial guidance on selecting material. 
In all cases, test the equipment with the chemicals you use 
under operating conditions.

i

Содержание MEMDOS SMART LB

Страница 1: ...inal Operating Instructions Lutz Jesco GmbH 2014 BA 10100 02 V02 Stepper Motor driven Diaphragm Dosing Pump MEMDOS SMART LB Operating Instructions Read the operating instructions The user is responsib...

Страница 2: ......

Страница 3: ...a 13 Other data 13 6 Dimensions 14 MEMDOS SMART LB 5 10 14 MEMDOS SMART LB 15 20 15 7 Installing the Dosing Pump 16 Set up information 16 Installation examples 16 8 Hydraulic installations 17 Dimensio...

Страница 4: ...ing signs represent the type and source of a danger 1 4 Identification of warnings Warnings are intended to help you recognise risks and avoid negative consequences This is how warnings are identified...

Страница 5: ...eck that all the screw connections have been tightened cor rectly and are leak proof WARNING Caustic burns or other burns through dosing media While working on the dosing head valves and connections y...

Страница 6: ...fication Any personnel who work on the dosing pump must have appropriate special knowledge and skills Anybody who works on the dosing pump must meet the conditions below Attendance at all the training...

Страница 7: ...iling point of the respective medium The materials of the dosing pump and hydraulic parts of the system must be suitable for the dosing medium that is used In this connec tion note that the resistance...

Страница 8: ...es that are difficult to access Delivery of dosing media for which the system is not designed Delivery of particulate or contaminated dosing media Inadequate protective clothing or none at all 3 6 6 I...

Страница 9: ...for external start stop 4 2 Scope of delivery Please compare the delivery note with the scope of delivery The following items are part of the scope of delivery Dosing pump MEMDOS SMART LB One set each...

Страница 10: ...he pressure in the dosing head the suction valve closes and the dosing medium flows through the discharge valve from the dosing head into the pressurised pipe 4 5 Ratings plate type label There is inf...

Страница 11: ...o run the pressure stroke and suction stroke at different speeds For low supply rates for example the dosing pump performs the suction stroke at the maximum speed and adjusts the speed of the pressure...

Страница 12: ...nufacturer With a viscosity of 300 mPas and above you must use spring loaded valves If the viscosity is above 1000 mPas this must be checked individually Information Value MEMDOS SMART LB size 5 10 15...

Страница 13: ...ead made of stainless steel 1 4571 C 0 80 Table 5 3 Permitted media temperatures Information Value MEMDOS SMART LB size 5 10 15 20 Voltage supply 110 240 V 10 5 50 60 Hz Power consumption W 25 Table 5...

Страница 14: ...osing head made of PVC PP or PVDF all dimensions in mm Fig 6 2 Dimensioned drawing of MEMDOS SMART LB 5 10 with dosing head made of stainless steel 1 4571 all dimensions in mm Connection Material Size...

Страница 15: ...15 20 Fig 6 3 Dimensioned drawing of MEMDOS SMART LB 15 20 with dosing head made of PVC PP PVDF or stainless steel 1 4571 all dimensions in mm 7 3 2 5 1 0 2 4 8 5 7 1 3 5 1 8 1 L L 84 70 6 5 100 116 1...

Страница 16: ...rounding equipment must be screened Avoid exposure to direct sunlight The dosing pump is not intended for use out of doors unless appro priate protective measures have been taken to prevent dust and w...

Страница 17: ...ing media The materials of the dosing pump and hydraulic parts of the system must be suitable for the dosing medium that is used Should this not be the case the dosing media may leak Depending on the...

Страница 18: ...ed vertically The suction valve must always point downwards Accordingly arrow and pressure valve always point upwards This is irrespective of the positioning of the dosing head to the drive 8 4 Hydrau...

Страница 19: ...on the grommet of connection piece 6 Screw the union nut onto the valve of the dosing pump Hose clip connected 8 4 2 Making the bonded connection Fig 8 4 Bonded connection Perform the following workin...

Страница 20: ...the downward opening Fig 8 6 Openings of the leakage drain 8 6 Connecting the dosing head venting facility The dosing heads of the MEMDOS SMART LB 5 and LB 10 have an inte grated dosing head venting u...

Страница 21: ...unctions Dosing the medium into a main line Preventing flowback into the pressure line through a non return valve Notes on assembly Double ball injection nozzles must be installed into the main line v...

Страница 22: ...o high Notes on assembly The line for returning dosing medium from the pressure relief valve must be routed to the dosing tank or to a collecting pan The pressure in the dosing tank must not be too hi...

Страница 23: ...liquid column due to too high acceleration However pulsation dampeners also have important safety functions since they prevent pressure peaks from arising that lead to piping vibrating and cause them...

Страница 24: ...air in the suction line and the dosing head in dosing systems with frequent downtimes Further advantages resulting from priming aids preventing cavitation in the suction line gas removal optical dosi...

Страница 25: ...e dosing head must be rinsed regularly to prevent depositing To do this you install a feed line for the rinsing medium water in the suction side installation Fig 8 15 Dosing of suspensions Dosing tank...

Страница 26: ...of the dosing tank in the case of a diaphragm rupture or pipe breakage Impermissibly high forces in the pump transmission that occur when dosing pumps receive the dosing medium directly from the pres...

Страница 27: ...ply This means that dosing medium can escape Depending on the type and haz ardousness of the dosing medium this can result in damage to property or to injury Install an emergency stop switch or integr...

Страница 28: ...from Lutz Jesco GmbH No liability is accepted for cables from other manufacturers Removing the conductive rubber band Fig 9 3 Conductive rubber band in connection socket 1 Remove the conductive rubber...

Страница 29: ...on The scale of the stroke frequency setting shows the value of the setting in percent from 0 stopped to 100 maximum possible stroke frequency Fig 10 1 Stroke frequency setting In terms of the stroke...

Страница 30: ...c parts Never look into open ends of plugged pipelines and valves CAUTION Danger of personal injury and material damage Dosing medium can escape if you loosen connections on the dosing head e g for ve...

Страница 31: ...in the metering container 3 Vent the dosing pump see 11 1 1 Venting the dosing pump 4 Set the stroke frequency to 0 5 Connect the power supply to dosing pump and set the stroke frequency to 100 within...

Страница 32: ...ing working steps 1 Unplug the dosing pump s mains plug from the power supply 2 Disconnect all electrical connections 3 Depressurize all the hydraulic parts in the system 4 Unplug all the hydraulic co...

Страница 33: ...sportation Should the unit be sent back to the manufacturer please follow chap ters Declaration of harmlessness see page 42 and Warranty appli cation see page 44 11 7 Disposal of old units The waste u...

Страница 34: ...all the screw connections have been tightened cor rectly and are leak proof CAUTION Danger of personal injury and material damage The dosing pump can generate a pressure that is many times the rated o...

Страница 35: ...gm flange so that the new diaphragm is not affected by dosing medium residues You have slightly greased the diaphragm thread e g using Molykote Longterm W2 1 Screw the diaphragm manually in the clockw...

Страница 36: ...the suction line Shut off valves closed Open the shut off valves Inspect the dosing pump for possible damage Suction head too high Set the dosing pump to feed or reduce the suction head Install a pri...

Страница 37: ...all a back pressure valve in the pressure line Pressure peaks due to accel eration with long suction lines Install a suction pressure regu lator Table 13 4 Type of fault Delivery rate varies Possible...

Страница 38: ...nstall a suction pressure regu lator The materials are not suitable for the dosing medium being used Check the resistance of the materials Diaphragm not screwed up to the end stop on the diaphragm rod...

Страница 39: ...arts kit containing 1 diaphragm 1 set of dosing head screws 1 set of washers only MEMDOS SMART LB 15 20 14 2 Dosing head spare parts kits including valves Spare parts set dosing head including screws...

Страница 40: ...ic back pressures These delivery capacities were determined on the manufacturer s test stands They apply at 20 C 68 F for water at 100 stroke frequency The delivery capacity depends on the medium dens...

Страница 41: ...uran a e de sa de das directivas CE indicadas A presente declara o perde a sua validade em caso de altera o ao equipamento n o autorizada por n s EN EC Declaration of Conformity We hereby certify that...

Страница 42: ...on for repair Dosing medium Description Irritating F Yes F No Properties Corrosive F Yes F No We hereby certify that the product has been cleaned thoroughly inside and outside before returning that it...

Страница 43: ...43 Lutz Jesco GmbH 2014 Subject to technical changes 140410 Stepper Motor driven Diaphragm Dosing Pump MEMDOS SMART LB Operating Instructions BA 10100 02 V02 Notes...

Страница 44: ...y application filled out Sender Company Phone Date Address Contact person Manufacturer order no Date of delivery Device type Serial number Nominal capacity nominal pressure Description of fault Servic...

Страница 45: ...13 Prohibited dosing media 7 E EC Declaration of Conformity 41 Electrical installation 27 Electrical specifications 13 External On Off via Release input 32 F Foreseeable misuse 7 Function description...

Страница 46: ...uspensions 25 System piping 18 T Technical specifications 12 Temperature Permitted ambient temperature 12 Permitted media temperatures 13 Tighten up dosing head bolts 35 Trained persons 6 Transportati...

Страница 47: ......

Страница 48: ...a Lutz Jesco GmbH Aredstra e 7 2 2544 Leobersdorf Austria Tel 43 2256 62180 Fax 43 2256 6218062 E mail info lutz jesco at Website www lutz jesco at Middle East Lutz Jesco Middle East FZE P O Box 9614...

Отзывы: