Delivery characteristic curves
40
Stepper Motor-driven Diaphragm Dosing Pump
MEMDOS SMART LB
© Lutz-Jesco GmbH 2014
Operating Instructions
BA-10100-02-V02
15 Delivery characteristic curves
This Chapter is intended to give you an idea of the delivery capacity
that the dosing pump can achieve at specific back pressures. These
delivery capacities were determined on the manufacturer's test stands.
They apply at 20 °C (68 °F) for water, at 100 % stroke frequency. The
delivery capacity depends on the medium (density and viscosity) and
temperature. Since these conditions vary at every installation location,
you should calibrate the dosing pump.
Fig. 15-1: Delivery characteristic curves MEMDOS SMART LB 5 – 20
Delivery c
apacity[l/h]
Pressure [bar]
LB 20
LB 15
LB 10
LB 5
25,0
20,0
15,0
10,0
5,0
0,0
0
2
4
6
8
10
12
14
16