Technical data
13
© Lutz-Jesco GmbH 2020
Subject to technical changes.
200318
BA-10491-02-V01
Piston diaphragm dosing pump
MEMDOS KMS LB/LA
Operating instructions
5 Technical data
Please note that some of this data only represents guide values. The actual capacity of a dosing pump depends on various factors.
5.1 Delivery capacity data
MEMDOS KMS LB/LA
14
20
30
60
100
140
200
285
400
320
500
700
Delivery capacity at max. back-
pressure
l/h
13.5
21
29.4
63.5
98.8
138
203
284
396
320.9 499.2
697
max. delivery pressure
bar
200
50
20
10
Max. stroke frequency
rpm
83
130
181
83
130
181
83
130
181
83
130
181
Suction lift for
non-gassing media
mWs
2
Tab. 9: Delivery capacity data MEMDOS KMS LB/LA
5.2 Operating conditions and limits
MEMDOS KMS LB/LA
14
20
30
60
100
140
200
285
320
400
500
700
Approved ambient temperature
°C
5 – 80*
Relative humidity
%
max. 90
Max. sound pressure level
dB(A)
57 – 65
Max. supply pressure
mbar
500
Viscosity limits
mPa∙s
300** / 1000***
Adjustable dosing range
%
0 – 100
Tab. 10: Operating conditions and limits MEMDOS KMS LB/LA
* Use of the dosing pump at ambient temperatures below 5 °C must be checked individually. In such cases, please contact the manufacturer.
** With a viscosity of ~300 mPa∙s and above, you must use spring-loaded valves.
*** If the viscosity is above 1000 mPa·s, this must be checked individually and the stroke frequency must be between 50 and 100 strokes/min.