Operation
32
© Lutz-Jesco GmbH 2020
BA-10491-02-V01
Piston diaphragm dosing pump
MEMDOS KMS LB/LA
Operating instructions
in the system.
n
Depending on the type of incident, you must depressurized the hy-
draulic connections or locked to prevent dosing medium from escap-
ing.
n
You must follow the safety data sheet of the dosing medium.
11.5 Storage
Storing the dosing pump correctly extends its service life. You should
avoid negative influences such as extreme temperatures, high humidity,
dust, chemicals, etc.
Ensure ideal storage conditions where possible:
n
The storage place must be cold, dry, dust-free and moderately venti-
lated
n
Temperatures b 2 °C and + 40 °C,
n
Relative air humidity must not exceed 90 %
11.6 Transportation
PLEASE NOTE
Machine damage caused by leaking oil
The oil inlet at the dosing pump cannot be closed completely tightly. Oil
may leak if the device is not transported in an upright position. This
might cause damage to the control unit or the motor.
ð
Drain the oil completely through the oil outlet before you transport
the dosing pump.
Perform the following working steps:
1.
Clean the device thoroughly. Any dangerous dosing media must be
additionally neutralised and decontaminated.
2.
Disassemble all accessories.
3.
Close all openings, so that no foreign objects can get into the system.
4.
The dosing pump must be suitably packed, preferably in the original
packing, for transportation.
5.
If the device is sent back to the manufacturer, please follow chapters
17 „Declaration of no objection“ on page 43 and 18 „Warranty
claim“ on page 44.
ü
The device can now be shipped.
11.7 Disposal of old equipment
n
Clean the device thoroughly. Any dangerous dosing media must be
additionally neutralised and decontaminated.
n
Dispose of dosing medium residue in the correct fashion.
n
Dispose the dosing pump in accordance with applicable local laws
and regulations. The device does not belong to household waste!
n
As the disposal regulations may differ from country to country in the
European Union, please consult your supplier if necessary.