Appropriate and intended use
Foreseeable misuse
9
© Lutz-Jesco GmbH 2014
Subject to technical changes.
140327
Solenoid-Diaphragm Dosing Pump
MAGDOS LP
Operating Instructions
BA-10231-02-V03
3.6 Foreseeable misuse
Below, there is information about the applications of the dosing pump or
associated equipment that are not considered to be intended use. This
chapter is intended to allow you to detect possible misuse in advance
and to avoid it.
Foreseeable misuse is assigned to the individual stages of the product
lifetime:
3.6.1 Faulty assembly
Unstable or unsuitable bracket
Dosing pump bolted wrongly or loosely
3.6.2 Faulty hydraulic installation
Suction and pressure lines dimensioned incorrectly
Unsuitable connection of the pipes due to wrong material or unsuit-
able connections.
Suction and pressure lines mixed-up
Damage to threads due to them being tightened too much
Bending of pipelines
No free return flow of the pressure relief valve
Excessive demand due to the pressure differences between the
suction and discharge valves
Through-suction at installation without back-pressure valves
Damage due to undamped acceleration mass forces
Exceeding the admissible pressure on the suction and discharge
sides
Using damaged parts
3.6.3 Faulty electrical installation
Connecting the mains voltage without a protective earth
Unsecured mains or one that does not conform to standards
Not possible to immediately or easily disconnect the power supply
Wrong connecing cables for mains voltage
Dosing pump accessories connected to wrong sockets
Diaphragm monitoring not connected or defective
Protective earth removed
3.6.4 Faulty commissioning
Commissioning with damaged plant
Shut-off valves closed at commissioning
Closed suction or pressure line, e.g. due to blockages
Personnel was not informed before commissioning
System was recommissioned after maintenance without all the
protective equipment and fixtures, etc. being reconnected.
Inadequate protective clothing or none at all
3.6.5 Faulty operation
Protective equipment not functioning correctly or dismantled
Modification of the dosing pump without authority
Ignoring operational disturbances
Elimination of operational disturbances by personnel without
adequate qualifications
Deposits in the dosing head due to inadequate purging, particularly
with suspensions
Bridging the external fuse
Operation made more difficult due to inadequate lighting or
machines that are difficult to access
Operation not possible due to dirty or illegible display of the dosing
pump
Delivery of dosing media for which the system is not designed
Delivery of particulate or contaminated dosing media
Inadequate protective clothing or none at all
3.6.6 Faulty maintenance
Carrying out maintenance during ongoing operation
Carrying out work that is not described in the operating instructions
No adequate or regular inspection of correct functioning
No replacement of damaged parts or cables with inadequate insula-
tion
No securing against reactivation during maintenance work
Using cleaning materials that can cause reactions with the dosing
media
Inadequate cleaning of the system
Unsuitable purging medium
Unsuitable cleaning materials
Cleaning materials left in system sections
Using unsuitable cleaning equipment
Using the wrong spares or lubricants
Contaminating the dosing medium with lubricant
Installing spares without following the instructions in the operating
manual
Blocking venting orifices
Pulling off sections of the plant
Contamination at installation without a dirt trap
Mixing up the valves
Mixing up the sensor lines
Not reconnecting all the lines
Damaging or not installing all the seals
Not renewing seals
Not paying attention to safety data sheets
Inadequate protective clothing or none at all
3.6.7 Faulty decommissioning
Not completely removing the dosing medium
Dismantling lines while the dosing pump is running
Device not disconnected from the power supply
Using the wrong dismantling tools
Inadequate protective clothing or none at all
3.6.8 Faulty disposal
Incorrect disposal of dosing media, operating resources and other
materials
No labelling of hazardous substances