Hydraulic installation
Hydraulic connections
18
Solenoid-Diaphragm Dosing Pump
MAGDOS LP
© Lutz-Jesco GmbH 2014
Operating Instructions
BA-10231-02-V03
8.4.1.2 Size 6/12
Fig. 8-3: Hose clip 6/12 (internal and external diameter in mm)
Size 6/12 hose clips only have a union nut. It clamps the hose onto the
grommet of the connection piece and at the same time fastens on the
dosing pump's valve.
Perform the following working steps:
1.
Cut the hose
to length neatly and at an exact right angle.
2.
Place a gasket that is suitable for the dosing medium between the
connection
and the valve.
3.
Push the union nut
and the cutting ring
over the hose
.
4.
Press the end of the hose
onto the grommet of connection
piece
. You can do this more easily by moistening the end of the
hose on the inside or applying some lubricant to the grommet in the
cone area. You should push at least two thirds of the hose onto the
grommet of the connection piece.
5.
Push the cutting ring
over the hose
into the cone area on the
grommet of connection piece
.
6.
Screw the union nut
onto the valve of the dosing pump.
Hose clip connected.
8.4.2 Making the bonded connection
Fig. 8-4: Bonded connection
Perform the following working steps:
1.
Cut the PVC tube to length.
2.
Push the union nut
onto the tube.
3.
Stick the bonded coupling sleeve
to the tube (follow the instruc-
tions of the adhesive manufacturer).
4.
Screw the union nut
onto the valve of the dosing pump. Use a
gasket that is suitable for the dosing medium.
Bonded connection made.
8.4.3 Making the cemented connection
Fig. 8-5: Cemented connection
Perform the following working steps:
1.
Cut the tube to length.
2.
Cut the thread
onto the end of the tube.
3.
Push the union nut
onto the tube.
4.
Seal the thread
.
When choosing your sealing material, take into
account its resistance to material, temperature and pressure.
5.
Screw the union nut
onto the valve of the dosing pump. Use a
gasket that is suitable for the dosing medium.
Cemented connection made.
Under normal conditions, you only need to screw the
hydraulic connections finger-tight. However, due to the mate-
rial settling, the pre-tension of the screw connection can
slacken. This means that you must re-tighten the screw
connection before carrying out commissioning.