Electrical installation
Principles
22
© Lutz-Jesco GmbH 2017
BA-10010-02-V01
Solenoid-diaphragm dosing pump
MAGDOS LA / LD
Operating instructions
9 Electrical installation
DANGER
Mortal danger from electric shock!
If there is an electrical accident, you must disconnect the dosing
pump from the mains as quickly as possible.
ð
Install an emergency stop switch or integrate the dosing pump
into the plant safety concept.
CAUTION
Danger of automatic start up!
The dosing pump does not have an ON/OFF switch and may start to
pump as soon as it is connected to the mains supply. This means
that dosing medium can escape. Depending on the type and
hazardousness of the dosing medium, this can result in damage to
property or to injury.
ð
Install an emergency stop switch or integrate the dosing pump
into the plant safety concept.
NOTE
Damage due to incorrect mains voltage
The dosing pump can be damaged if you connect it to the wrong
mains voltage.
ð
Observe the information on the mains supply that is given on
the rating plate.
NOTE
Insufficient electromagnetic compatibility
When you connect the dosing pump to a socket without an
attached protective earth, it is not possible to guarantee the
interference radiation and interference immunity according to EMC
regulations.
ð
Only connect the dosing pump to sockets with an attached
protective earth.
9.1 Principles
n
The dosing pump is fitted with a 115 V AC or 230 V AC (50 / 60 Hz)
power supply unit.
n
The electrical connection comply with local regulations.
n
The dosing pump must be plugged into a grounded power outlet.
n
To avoid dosing errors at the end of the process, the dosing pump
must be locked electrically.
n
The dosing pump must not be operated by switching the mains
voltage on or off.
n
Signal cables must not be laid parallel to high-voltage current lines or
mains cables. You must route supply and signal lines in separate
channels. An angle of 90° is required at line crossings.
NOTE
Conducting rubber hoses with versions LA and LD
The MAGDOS LA and LD are delivered with two conductive rubber
hoses installed in connection sockets 1 and 3. These conduct
electricity and ensure that the contacts in the connection sockets
remain closed when no cables are connected. If the conductive
rubber bands in connection sockets 1 and 3 are missing or not
correctly installed and there are no cables connected to the
sockets, it is not possible to start the dosing pump.
ð
Insert the conductive rubber bands in connection sockets 1 and
3 if there are no cables connected to the connection sockets.
ð
Ensure that the conductive rubber band is installed on the
correct contacts (see instructions in following chapters).
ð
Retain the conductive rubber hoses so that you can change the
assignment of the connection ports later.
Fig. 16: Conductive rubber hoses in the connections 1 and 3 of the MAGDOS LA/LD