Normal Operation

In normal operation, the following buttons allow the user to ac-
cess certain basic functions:

1.   

(Raise)

  —  QSN-4T16-S: Raises zone light level in 1% incre-

ments from 0-100%.

   

— QSN-4S16-S: Turns selected zone on.

2.   

(Lower)

 —  QSN-4T16-S: Decreases zone light level in 1% 

decrements from 100-0%.

   

— QSN-4S16-S: Turns selected zone off.

Note:

  On QSN-4T16-S only - For any zone, simultaneously 

pressing and holding the   and   buttons will toggle the 
zone between high end and low end.

QS Link Input(s) Setup

seeTouch

 QS Wallstation or GRAFIK Eye

®

 QS unit - Scenes 

and Off

Assigns a 

seeTouch 

QS Wallstation or 

GRAFIK Eye 

QS unit to any 

Energi Savr Node

 unit zone on the QS link.

1. To assign a 

seeTouch

 QS Wallstation or 

GRAFIK Eye 

QS unit to 

an 

Energi Savr Node

 unit(s), simultaneously press and hold the 

top and bottom buttons on the wallstation or 

GRAFIK Eye

 QS 

unit for 3 seconds. The QS link enters Programming Mode. The 
sensor LEDs on the 

Energi Savr Node

 unit(s) will flash sequen-

tially through each input and group.

2. To assign or un-assign desired zone(s) to a wallstation, simul-

taneously press and hold the the   and   buttons for the desired 
zone. A blinking ‘Zone’ LED indicates an assigned zone. 

3. To exit Programming Mode, simultaneously press and hold the 

the top and bottom buttons on the wallstation or 

GRAFIK Eye

 QS 

unit for 3 seconds. 

 

Note:

  For more advanced programming information, refer to the 

online Programming Guide at:  
www.lutron.com/softswitchenergisavrnode

Using LEDs to troubleshoot

WARNING! Danger of Shock. May result in serious 
injury or death.

 DO NOT WIRE WHEN LIVE! Switch off 

power to all power feeds via circuit breaker before wiring 
or servicing the 

Energi Savr Node 

unit.

Buttons and LEDs in the unit are used for programming and 
troubleshooting. 

If line voltage shield is removed, the unit 

must be accessed by a certified electrician, following local 
codes.

LED

LED Behavior

Description

Occ

 

(Occupancy 
Sensor)

Continuous On

Sensor detects Vacancy

1 flash per second

Sensor detects  
Occupancy

Off

Sensor never detected

Photo 

(Daylight 
Sensor )

Continuous On

Sensor is detected

Flashing

Sensor information  
transmitting on the QS link

Off

Sensor never detected/
sensor not seeing light

IR

 

(Infrared 
Receiver)

Continuous On

Receiver is detected

Flashing

IR button press detected

Off

Receiver never detected

Switch

 

(NEC

®

 

Class 2 
Switch)

Continuous On

Switch detected/open

Flashing

Switch button press  
detected

Off

Switch never detected

CCI

 

(Contact Clo-
sure Input)

Continuous On

Contact detected/open

Flashing

Contact closed

Off

Contact never detected

Emerg

 

(Emergency 
Contact Clo-
sure Input)

Continuous On

Normal operation/Contact 
Closed/Jumpered

Rapid flash

Emergency Mode/Contact 
Open/Jumper missing

QS Link

On/Flashing

Device transmitting/ 
receiving on the QS link

3 quick flashes  
every 4 seconds

Communication error

Off

Device not transmitting/
receiving on the QS link

Wired

Continuous On

Wired sensor

Zone

Continuous On

Load is on

Off

Load is off

Содержание Energi Savr Node QSN-4S16-S

Страница 1: ...re inputs 7 QS link wiring 8 Applications 10 Out of box functionality 10 Normal operation 11 QS link input s setup 11 Troubleshooting 11 Warranty 12 Contact information 12 System Example Programming Guide available at www lutron com softswitchenergisavrnode QS link Control Power 120 277 V 4 Load Input Feeds 120 277 V 4 0 10 V Channels QSN 4T16 S only Emergency Contact Closure Input Contact Closure...

Страница 2: ...rgency contact closure input defaults to Emergency Mode in the absence of a contact closure across the input The QS Link can have up to 100 zones and 100 devices The Energi Savr Node unit counts as 1 device and 4 zones on the QS link In a system with multiple Energi Savr Node units on a QS link a maximum of 100 daylight sensors 100 occupancy sensors 100 IR receivers and 100 Pico wireless controlle...

Страница 3: ...ltage to power the Energi Savr Node unit WARNING Danger of Shock May result in serious injury or death DO NOT WIRE WHEN LIVE Switch off power to all power feeds via circuit breaker before wiring or servicing the Energi Savr Node unit Buttons and LEDs in the unit are used for programming and troubleshooting If wiring is exposed when accessing buttons and LEDs the unit must be accessed by a certifie...

Страница 4: ...0 10 V Zones QSN 4T16 S only Feed Through Wiring Example 1 4 Circuits Multiple Feeds Switched Hot 1B Hot Feed 1A Hot Feed 2A Hot Feed 3A Hot Feed 4A Switched Hot 2B Switched Hot 3B Switched Hot 4B Ground Bar Neutral Wires Distribution Panel LOAD LOAD LOAD LOAD 0 10 V Wiring QSN 4T16 S only 20 AWG to 12 AWG 0 5 mm2 to 4 0 mm2 Strip length 1 4 in 6 mm Torque 5 in lbs 0 5 N m Connect only NEC Class 2...

Страница 5: ...mm2 to 4 0 mm2 Strip length 1 4 in 6 mm Torque 5 in lbs 0 5 N m Connect only NEC Class 2 PELV circuits or connect only non NEC Class 2 PELV circuits to 0 10 V zones 1 4 0 10 V zones 1 4 are not isolated from each other Negative terminals are not internally connected to each other both positive and negative connections must be made Follow all national and local codes for separation requirements Loa...

Страница 6: ...he input terminals are shown below WARNING Danger of Shock May result in serious injury or death DO NOT WIRE WHEN LIVE Switch off power to all power feeds via circuit breaker before wiring or servicing the Energi Savr Node unit Buttons and LEDs in the unit are used for programming and troubleshooting If line voltage shield is removed the unit must be accessed by a certified electrician following l...

Страница 7: ...ollow all applicable national and local codes for proper circuit separation and protection CCI input must be used with dry contact closure devices If the Emergency input is open the Energi Savr Node unit will enter Emergency Mode which will turn on all loads and disable local zone control and control from sensors and QS devices Note The Energi Savr Node unit will default to Emergency Mode if the E...

Страница 8: ...shielded from Belden model 9461 Check for compatibility in your area A QS system can have up to 100 zones and 100 devices The Energi Savr Node unit counts as 1 device and up to 4 zones See diagram on the right for QS link wiring 1 Connect terminals 1 3 and 4 to all Energi Savr Node units 2 Each Energi Savr Node unit has its own built in power supply 3 The terminal 2 connection 24 V supplies power ...

Страница 9: ...nstallation Guide Energi Savr Node unit Sivoia QS Shade Sivoia QS Smart Power Panel seeTouch QS Wallstations QS Control Link Sivoia QS Smart Power Panel Sivoia QS Shade seeTouch QS Wallstations Energi Savr Node unit QS Control Link QS Link Wiring continued Daisy chain Wiring Example T tap Wiring Example ...

Страница 10: ... level QSN 4T16 S only Corresponding zone light levels will raise or lower when light sensed by daylight sensor falls or rises based on a factory default setting IR Receivers IR See IR Receiver literature for compatible transmitters Corresponding zones respond to on off and Scene commands from compatible IR transmitters QSN 4T16 S only Corresponding zones respond to Raise and Lower commands from c...

Страница 11: ...it for 3 seconds Note For more advanced programming information refer to the online Programming Guide at www lutron com softswitchenergisavrnode Using LEDs to troubleshoot WARNING Danger of Shock May result in serious injury or death DO NOT WIRE WHEN LIVE Switch off power to all power feeds via circuit breaker before wiring or servicing the Energi Savr Node unit Buttons and LEDs in the unit are us...

Страница 12: ... TO MEET ANY DUTY INCLUDING OF GOOD FAITH OR OF REASONABLE CARE NEGLIGENCE OR ANY OTHER PECUNIARY OR OTHER LOSS WHATSOEVER NOR FOR ANY REPAIR WORK UNDERTAKEN WITHOUT LUTRON S WRITTEN CONSENT ARISING OUT OF OR IN ANY WAY RELATED TO THE INSTALLATION DEINSTALLATION USE OF OR INABILITY TO USE THE UNIT OR OTHERWISE UNDER OR IN CONNECTION WITH ANY PROVISION OF THIS WARRANTY OR ANY AGREEMENT INCORPORATIN...

Отзывы: