background image

LGMRU4X4 v2 Masthead Relay Unit Installation Handbook.

 

 

 

Page 14

 

WALK TEST.   

See Test Mode on page 9.  With the LGMRU4x4v2 in test mode, when an 

alarm event is received it will be re

-

transmitted back out so that it can be received on a 

WALK TEST Instrument. 

 

This is useful for testing the wireless range from the PIR detector.

 

Do not leave the LGMRU4x4v2 in walk test mode as this uses a lot more air time and 

could cause Missing Call error messages on systems with large numbers of detectors.

 

 

Sub Net use.

 

Page 15 shows PIR detectors communicating directly with an LGMRU4x4v2 and also via 

repeaters (LGMT4x4)

 

Where repeaters are used it is necessary to use more sub nets as shown.

 

 

 

LGMRU

 

4X4

 

Repeater

 

Repeater

 

To alarm pre

-

sets.

 

U

lin

k

 

D

ow

lin

k

 

Walk Tester

 

The Walk Test Instrument does not take any notice of Sub Net codes and will receive 

from anywhere on the site either directly from the Masthead or via Repeaters.

 

All these products will be set to the same Site Code. 

 

INDEX

 

page

 

LGMRU4X4.v2  Masthead Relay Unit Installation Handbook.

 

 

 

Page 3

 

Introduction

 

4

 

Features

 

5

 

Mode switches and connections

 

4

 

LGMRU4x4v2 Layout

 

6

 

Layout and Fitting the LGREM4x4v2 expansion module

 

6

 

Wiring

 

7

 

Programming

 

8

 

Menu options level 1

 

9

 

Menu options levels 2 & 3

 

10,11

 

Key Fob learning and default settings

 

12

 

Examples

 

13

 

Walk test 

 

14

 

Sub Net use

 

15

 

Содержание Genesis LGMRU4x4

Страница 1: ...ce unit LGDM16 16 way relay unit with end of line resistor LGRU16ELR 3 versions Relay module with end of line resistor LGRM8ELR 3 versions Optional antenna AE434 Transmitter module LGTX434 Key Point L...

Страница 2: ...transport container in the event that a unit has to be returned for any reason Servicing This unit should not require general servicing Any repair work should only be undertaken by Luminite Electroni...

Страница 3: ...U4x4v2 and also via repeaters LGMT4x4 Where repeaters are used it is necessary to use more sub nets as shown LGMRU 4X4 Repeater Repeater To alarm pre sets Up link Down link Walk Tester The Walk Test I...

Страница 4: ...are ALARMs 16 PIRs are processed then the processed PIRs are units 1 16 Example 3 Unit 1 Configuration 2 expansion module is NOT fitted which means we have 8 relays 4 pairs of ALARM TAMPER 4 PIRs are...

Страница 5: ...y A1 It is the lowest PIR index processed by this Receiver The highest PIR index processed depends on number of relays available i e whether expansion module is fitted or not and also on Configuration...

Страница 6: ...from EEPROM on power up EM Extra mode 0 normal mode 1 extra mode prints content of Learned_Keyfobs entire EEPROM for debug Value Function 00 no_function relay permanently Off stays Off on power failu...

Страница 7: ...ia Keyfobs also INHIBIT INHIBIT has priority SC Start Index for ARM DISARM Control 1 64 default 1 EC End Index for ARM DISARM Control 1 64 default 64 LGMRU4X4 v2 Masthead Relay Unit Installation Handb...

Страница 8: ...tt Tamper time 0 to 99 default 2 seconds IA Alarm state idle 0 N O 1 N C default 0 It Tamper state idle 0 N O 1 N C default 0 LC Light control 0 to 64 default 0 tM Test mode 0 1 default 0 Site codes s...

Отзывы: