LGMRU4X4.v2  Masthead Relay Unit Installation Handbook.

 

 

 

Page 4

 

Introduction.

 

 

The Genesis LGMRU4x4.v2 Masthead Relay Unit is a receiver for Genesis wireless 

PIR detectors and provides a simple interface for virtually any kind of alarm input.  

 

 

Powered from 12 volts DC and weather proof to IP66 it is ideal to be fitted externally 

with a dome camera and connected directly into the alarm pre

-

sets.

 

 

This product may also be connected to any other kind of alarm system and is very 

versatile due to its new improved features such as key fob control and remote arm/

disarm. 

 

 

Two auxiliary outputs can be used to provide keyfob control of devices such as 

 

electric door release and lighting.  Grouped tampers or alarms may also be applied to 

these outputs.

 

 

Choose between either 4 alarm outputs with corresponding tampers or eight alarm 

outputs without tampers.   An expansion card is available to increase the number of 

alarm outputs to a maximum of 16. (LGREM4x4.v2)

 

 

Only PIRs that are between the "lowest PIR index" and "highest PIR index"

 

are processed, i.e. mapped to one of relays.

 

All others (that are out of this range) are ignored, filtered

-

out on reception !

 

 

 

Example 1:   Unit = 1, Configuration = 1, expansion module is NOT fitted which 

means we have 8 relays. 

 

All 8 relays are ALARMs => 8 PIRs are processed then the processed PIRs are 

units 1..8

 

 

Example 2:   Unit = 1, Configuration = 1, expansion module is fitted which means 

we have 16 relays, all 16 relays are ALARMs => 16 PIRs are processed; then the 

processed PIRs are units 1..16

 

 

Example 3:  Unit = 1, Configuration = 2, expansion module is NOT fitted which 

means we have 8 relays, 4 pairs of ALARM+TAMPER => 4 PIRs are processed;

 

then the processed PIRs are units 1..4

 

 

Example 4: Unit = 1, Configuration = 2, expansion module is fitted which means we 

have 16 relays, 8 pairs of ALARM+TAMPER => 8 PIRs are processed; then the 

processed PIRs are units 1..8

 

 

Example 5: Unit = 20, Configuration = 1, expansion module is NOT fitted which 

means we have 8 relays, all 8 relays are ALARMs => 8 PIRs are processed;                  

then the processed PIRs are units 20..27

 

 

Example 6: Unit = 62, Configuration = 2, expansion module is fitted which means 

we have 16 relays, 8 pairs of ALARM+TAMPER => 8 PIRs are processed;

 

then the processed PIRs are units 62..64 (maximum index)

 

=> processed PIRs are units 62..64

 

(only 3 pairs A+T will operate, all other relays remain Idle)

 

 

Note 2: If Function_1 is Global_Alarm or Global_Tamper, then parameters S1,E1 

specify the Start and End PIR index that are included.

 

If Function_2 is Global_Alarm or Global_Tamper, then parameters S2,E2 specify

 

the Start and End PIR index that are included.

 

 

Start and End indexes must be set correctly.

 

If not, then Receiver makes some automatic corrections:

 

If Start is lower then the index of the lowest mapped PIR then the lowest mapped 

PIR index is used as Start instead.

 

If End is higher then the index of the highest mapped PIR then the highest mapped 

PIR index is used as End instead.

 

If End is lower than Start, then group consists of only 1 PIR, the one with index 

start.

 

LGMRU4X4.v2  Masthead Relay Unit Installation Handbook.

 

 

 

Page 13

 

Содержание Genesis LGMRU4x4

Страница 1: ...ce unit LGDM16 16 way relay unit with end of line resistor LGRU16ELR 3 versions Relay module with end of line resistor LGRM8ELR 3 versions Optional antenna AE434 Transmitter module LGTX434 Key Point L...

Страница 2: ...transport container in the event that a unit has to be returned for any reason Servicing This unit should not require general servicing Any repair work should only be undertaken by Luminite Electroni...

Страница 3: ...U4x4v2 and also via repeaters LGMT4x4 Where repeaters are used it is necessary to use more sub nets as shown LGMRU 4X4 Repeater Repeater To alarm pre sets Up link Down link Walk Tester The Walk Test I...

Страница 4: ...are ALARMs 16 PIRs are processed then the processed PIRs are units 1 16 Example 3 Unit 1 Configuration 2 expansion module is NOT fitted which means we have 8 relays 4 pairs of ALARM TAMPER 4 PIRs are...

Страница 5: ...y A1 It is the lowest PIR index processed by this Receiver The highest PIR index processed depends on number of relays available i e whether expansion module is fitted or not and also on Configuration...

Страница 6: ...from EEPROM on power up EM Extra mode 0 normal mode 1 extra mode prints content of Learned_Keyfobs entire EEPROM for debug Value Function 00 no_function relay permanently Off stays Off on power failu...

Страница 7: ...ia Keyfobs also INHIBIT INHIBIT has priority SC Start Index for ARM DISARM Control 1 64 default 1 EC End Index for ARM DISARM Control 1 64 default 64 LGMRU4X4 v2 Masthead Relay Unit Installation Handb...

Страница 8: ...tt Tamper time 0 to 99 default 2 seconds IA Alarm state idle 0 N O 1 N C default 0 It Tamper state idle 0 N O 1 N C default 0 LC Light control 0 to 64 default 0 tM Test mode 0 1 default 0 Site codes s...

Отзывы: