Copyright 2018 Luminite Electronics Ltd
All rights reserved. Unauthorised duplication of this handbook by any means
mechanical or electrical, is strictly prohibited without the express written permission of
Luminite Electronics Ltd.
Luminite Electronics Ltd acknowledge all registered trademarks
Luminite Electronics Ltd reserve the right to make changes to this handbook and to its
products without prior notice in order to improve design or performance characteristics.
PRE
-
INSTALLATION NOTES
Unpacking
.
On receipt, inspect the package and contents for signs of damage. If damage has oc-
curred, advise the carrier and/or suppliers immediately. Inspect the contents to confirm
that all items are present and undamaged. If any items are missing or damaged, contact
the supplier immediately. It is advisable that the original carton is retained as this forms
the safest transport container in the event that a unit has to be returned for any reason.
Servicing.
This unit should not require general servicing. Any repair work should only be
undertaken by Luminite Electronics Ltd.
Moisture.
Do not expose the internal electronics of this unit to moisture i.e. take care during
installation not to allow rain or damp into the product. When the product is sealed it is
water resistant to IP66.
Box Contents.
1 x
GENESIS
Masthead Relay Unit LGMRU4x4.v2
1 x 1/4 wave antenna
LGMRU4X4.v2 Masthead Relay Unit Installation Handbook
Page 2
LGMRU4X4 v2 Masthead Relay Unit Installation Handbook.
Page 15
PIR
’
s communicating directly with the
LGMRU4x4v2
All Sub Nets are 1.
The other two examples
show examples where
one or more repeaters are
used and how the Sub
Net Codes separate the
system.
SUBNET 1
PIR
PIR
PIR
PIR
1 4X4
4X4
SYSTEM
CONTROLLER
KEY
SUBNET 1
SUBNET 2
SUBNET 3
REP
PIR
PIR
PIR
PIR
PIR
PIR
PIR
REP
4X4
SYSTEM
CONTROLLER
1 4X4 &
2 Repeaters
KEY
1 4X4 &
1 Repeater
SUBNET 1
SUBNET 2
SYSTEM
CONTROLLER
4X4
PIR
PIR
PIR
PIR
PIR
PIR
REP
KEY