6

www.luminite.co.uk

same site number. Although it cannot be set with a unit number, it counts 

as one of the 64 units and reduces the total available units to 63.

Call Repeat

Master Unit

Call Period

Time Set

Enables or disables which units can act as a repeater to relay the wireless 

transmission across longer distances. 

Call repeating is disabled by default 

and should only be enabled on units that are required to create a larger 

mesh network as battery life is affected.

 Alertex sounder or annunciator 

/ beacon units have a wireless transmission range of up to 1km. Units set 

to call repeat can relay the transmission up to 16 times out of the initial 

1km radius, providing a maximum line of sight transmission range of up 

to 16km.

Enables  or  disables  which  units  are  identified  as  Master  units.  Master 

units are the only units that are able to reset the system post-activation 

and are fitted with a master reset key. 

Determines how frequently the units will check in with the IP Masthead 

to give their status and provide updates such as low battery or poor signal 

notifications. The frequency of the call period can be set from 3 to 99 

minutes and is 

set to 99 minutes by default.

 From 3 to 50 minutes, the 

value can be increased and decreased in 1 minute increments (ie. 4, 5, 6, 

7, etc...). From 50 to 99 minutes, the value can be increased and decreased 

in 5 minute increments (ie. 55, 60, 65, etc...). 

More frequent call periods 

can affect the battery life of Alertex units.

Determines how long the sounder or annunciator / beacon will produce 

an audible alert. 

By default, it is set to 10 minutes.

 This means that after 

the initial 10 minute period is over, the units will stop creating an audible 

alert but will continue to produce a visible alert. The beacon can be set 

to produce an audible alert from 1-30 minutes. Setting the TS to 0 will 

cause the beacon to produce an audible alert indefinitely until the system 

is reset.

Содержание Alertex NXECSB

Страница 1: ...s with optional Call Points for Fire Alert and Lockdown Wireless Critical Alert System 2a Bellevue Road Friern Barnet London N11 3ER info luminite co uk 020 8368 7887 Luminite Electronics Ltd www luminite co uk NXISB NXESB NXIVB NXEVB NXICSB NXECSB NXICVB NXECVB V3 ...

Страница 2: ...2 www luminite co uk ...

Страница 3: ... site and each unit is totally wireless and battery powered Each unit has the ability to act as a repeater and can relay the transmission up to 16 times outside the initial wireless range in order to navigate large or difficult sites Alertex can be used as a standalone system or can be monitored and controlled from one centralised location by incorporating a Genesis IP Masthead Receiver allowing t...

Страница 4: ... system a maximum potential range of 16km line of sight Alertex call points only keyfobs and smoke and heat detectors do not act as repeaters Quick Start 1 Remove the lid using a screwdriver to undo the push and quarter turn screws 2 Taped inside the lid you will find a black plastic reset key for units with a fitted call point along with the power jumper JP2 The black reset key is used for resett...

Страница 5: ...uld be left on the default setting Unit numbers identify individual Alertex units on the site There are 64 unit numbers available which is the maximum number of Alertex units per site If an IP Masthead is used with the system then this must have the Name Range Default Description SI 1 32 1 Site Number SU 1 8 1 Subnet Number Un 1 64 1 Unit Number Cr 0 1 0 Call Repeater 1 Enabled 0 Disabled CP 3 99 ...

Страница 6: ...he system post activation and are fitted with a master reset key Determines how frequently the units will check in with the IP Masthead to give their status and provide updates such as low battery or poor signal notifications The frequency of the call period can be set from 3 to 99 minutes and is set to 99 minutes by default From 3 to 50 minutes the value can be increased and decreased in 1 minute...

Страница 7: ...o save the value and move on to the UNIT value UN 7 Use the Up and Down buttons to change the UNIT number value 8 Press Select again to save the value and move on to the CALL REPEAT value Cr 9 Use the Up and Down buttons to change the CALL REPEAT value 10 Press Select again to save the value and move on to the CALL PERIOD value CP 11 Use the Up and Down buttons to change the CALL PERIOD value 12 P...

Страница 8: ... and switches 7 and 8 are to adjust the volume When both switches are in the UP position this is the maximum sound level Switch 7 UP and switch 8 DOWN will reduce the sound by 10 decibels Switch 7 DOWN and switch 8 UP will reduce the sound by 20 decibels On Sounder variants the sound volume and sound pattern can be adjusted using the dip switches on the back of the sounder On Annunciator variants ...

Страница 9: ...larm HF 18 Alternating Tones 2400Hz 2900 Hz at 3 Hz UDDDU Alternate HF 19 500 Hz rising to 1200 Hz over 3 5 sec silence 0 5 sec DUDDU Slow Whoop 20 1200 Hz falling to 500 Hz over 1 sec silence 10mS UUDDU Din Tone DK 21 554 Hz for 100 mS and 440 Hz over 1 sec silence 10mS DDUDU French Fire Sounder 22 420 Hz reapeting 0 625 sec on 0 625 sec off UDUDU Australian Alert Signal 23 500 Hz to 1200 Hz swee...

Страница 10: ...ts returns to flashing once a second This will take a minite or so 9 When the LED returns to flashing once a second another callpoint can be tested 10 To test another call point go back to number 6 11 To take the system out of silent test mode turn master unit key clockwise for 3 seconds and return to the neutal position 12 Waitfor the LED on the master unit to go out The sytem is now operating no...

Страница 11: ...perform the reset action again 5 Please take care when removing the lid of the Alertex unit as excessive force may disconnect the wires from the sounder or annunciator beacon 6 Please take care when removing the top of the sounder or annunciator beacon to change the sound pattern or volume as excessive force my disconnect the wires within the unit Connect to the IP Masthead Receiver Setting up the...

Страница 12: ...t mode is selected by default and allows you to test units Live mode enables you to monitor units and get live activation updates from the system You cannot test in live mode and you cannot monitor in edit mode Tick the Live mode box to enable live mode and deselect it to enable edit mode 8 Click on the blue Connect button to connect the app to your IP masthead Set up Your Alertex Units 1 Navigate...

Страница 13: ...reen 11 Select the type of test you want to perform from the bottom drop down menu and click the Send button to initiate the test 12 To cancel the test click on the Clear button above Send 13 Make sure to save your changes by clicking Save Setup in the top right corner Larger Sites For larger sites you can use the Genesis masthead and walk tester LGWT434 to establish the wireless range of Alertex ...

Страница 14: ...the email addresses of the recipients of notifications into the To boxes underneath Email 1 Email 2 and Email 3 5 Type the email address for the SMTP server in the From boxes underneath Email 1 Email 2 and Email 3 6 Select the notifications that recipients will receive by ticking the event boxes on the left underneath Events that trigger email notification 7 Alertex specific events are Alertex Act...

Страница 15: ...15 www luminite co uk ...

Страница 16: ...16 www luminite co uk 2a Bellevue Road Friern Barnet London N11 3ER info luminite co uk 020 8368 7887 Luminite Electronics Ltd www luminite co uk ...

Отзывы: