Note 1: Pin numbering and colour in accordance with ANSI/TIA/EIA-568 scheme T568B.
Note 2: Pin 8 should be wired as signal common even if pins 3 and 6 are NOT wired so that both conductors
7 and 8 are at equal potential.
Data 2 is NOT being used in the LumiNode4
DIN
.
TERMINAL BLOCK PIN-OUT
For the LumiNode4DIN equipped with terminal blocks we are using the following connection schedule:
RJ45 PIN-OUT
For the LumiNode4DIN equipped with RJ45 ports we are using the following connection schedule from
the ANSI E1-11 DMX Standard: Table 4 Connection Schedule for DMX512 Equipment Using IEC 60603-7-8
Position Modular Connectors:
8 | teCHnICal sPeCIfICatIons
37
Pin (Wire)
Wire Colour
DMX512 Function
1
White/Orange
Data 1+
2
Orange
Data 1-
3
White/Green
Data 2+ (optional)
4
Green
Data 2- (optional)
5
Blue
Not assigned
6
White/Blue
Not assigned
7
White/Brown
Data link common (common reference) for data 1 (0V)
8
Brown
Data link common (common reference) for data 2 (0V)
Pin (Wire)
DMX512 Function
1
Ground
2
Data -
3