INPUT
A process engine supports the following inputs:
DMX:
A DMX source, such as a lighting control desk, can be connected to any of the DMX port(s) of the LumiNode.
You will need to use a male to male adaptor to connect the console to the DMX port of the LumiNode.
In the input configuration, you click on the port you wish to use as an input port, to enable the DMX input.
A greyed-out port with a diagonal bar in it means this port is already used.
Art-Net:
Any Art-Net controller can be used as an input for the process engine. The LumiNode supports all Art-Net
revisions, including Art-Net IV.
Tick the box to select Art-Net as an input protocol.
Here you can add the universe number you wish to use, and you can specify the IP address of the source.
If you leave the source IP field 0.0.0.0 any source in the network outputting this universe will be used. The
LumiNode process engine will bind this input to the first source using this universe number.
For a better identification of the source, you can add a text to your Art-Net input.
Advanced settings:
Next to the Source IP field you find a cog wheel for advanced settings:
Accept Own Data. In some cases, it is required to ignore the Art-Net data generated by the LumiNode
itself. When disabled the LumiNode will only listen to other sources in the network.
By default, the Accept Own Data is enabled.
sACN:
Any sACN controller can be used as an input for the process engine.
Tick the box to select sACN as an input protocol.
Here you can add the universe number you wish to use, and you can specify the IP address of the source.
If you leave the source IP field 0.0.0.0 any source in the network outputting this universe will be used. The
LumiNode process engine will bind this input to the first source using this universe number.
For a better identification of the source, you can add a text to your sACN input.
Advanced settings:
Next to the Source IP field you find a cog wheel for advanced settings:
Per-channel Priority Mode. To better handle multiple source control scenarios, the 0xDD sACN start code
has been introduced to allow setting a source priority for each channel of a universe.
5 | lumInoDe In DetaIl