ISR 12-LO
•
IGAR 12-LO Operating Manual
Settings / Parameter Descriptions
•
23
4
Settings / Parameter Descriptions
Certain settings must be done for use of the entire specifications of the pyrometer. The
most settings can be done at the instrument directly, a few (e.g. setting of
contamination level) only via software InfraWin.
After removing the cover of the housing, the setting keys of the pyrometer are accessible.
Note:
Please make sure that the pyrometer is not contaminated while open.
4.1
Factory settings
Temperature display (°
C / °F
) = °C
Emissivity (
ε
) = 1.000
Emissivity slope (K) = 1.000
Exposure time (
t
90
) = 0.00
Clear time (
t
Clear
) = 0.00
Operating mode (1 / 2 / M) = 2
Max / min = maximum value storage preset
Analog output (0 / 4 mA) = 0 ... 20 mA
Sub range (from / to) same as basic temperature range
Address = 00
Switch-off limit = 10%
Baud rate (kBaud) = 19.2 kBd
Switch for interface (RS485 / RS232) = RS232
Warning level “dirty window“ = 0% (equivalent to “off”)
4.2
Instrument settings
Certain settings must be done for use of the entire specifications of the pyrometer. The most
settings can be done at the instrument directly, a few (e.g. setting of contamination level) only
via software InfraWin.
After removing the cover of the housing, the setting keys of the pyrometer are accessible.
Note:
Please make sure that the pyrometer is not contaminated while open.