For open containers, you can use a bracket for installation. Pay attention to the bearing capacity of the
bracket to keep a certain distance between the sensor and the container wall. If the top and bottom of
the open container or silo are flat, there is no material hanging, and there are no other objects on the
inner wall, then the distance between the sensor and the container wall is shown in the following table:
4.2.5.3 Open container
On the open container-the bracket is
installed on the top side
Since the open container has no focusing effect,
The sensor can be installed in the middle of the container.
On open container--top centered
bracket installation
Maximum range
5m
20m
50m
Smallest
Distance from the wall
0.5m
2.5m
6m
Maximum range
10m
30m
60m
Smallest
Distance from the wall
1.0m
3.5m
7m
Maximum range
15m
40m
70m
Smallest
Distance from the wall
1.5m
5m
8m