Chapter 5 Configuring Ports and Channels Using the AQueView
®
EMS
Obtaining Module Hardware Information
5-22
255-700-243
PacketStar
®
PSAX 12-Port Medium-Density DS1 Multiservice Module User Guide
, Issue 1
Release 8.0
Table 5-6. Field Descriptions for the Module Information Window
Field Name
Field Values
Description
Module Type
Default:
N/A
Range: from PSAX
system database
Format: Predefined
alphanumeric alpha-
numeric
Indicates the name of the module in the slot. All
modules supported by the PSAX systems and the
AQueView
system are listed in the section "I/O
and Server Modules" in this chapter.
Operational Status
Default:
Unknown
Range: N/A
Format: Predefined
alphanumeric
Displays the operational mode of the module.
Unknown
Indicates that the module has not been config-
ured.
Primary
For an I/O or server module, indicates that at
least one port or channel on the module has been
configured.
For a CPU module, indicates that this module is
the primary CPU module.
Standby
Indicates that the module, in redundant systems,
is operating as the backup module to the primary
module.
Indicates for the CPU module, in redundant sys-
tems, that this module is the backup CPU mod-
ule.
Alarm Status
Default:
No Alarm
Range: N/A
Format: Predefined
alphanumeric
Displays the present alarm condition of the mod-
ule. For the alarm status conditions, see the table
“Alarm Status Descriptions” following these field
descriptions.For the alarm status conditions, see
“Obtaining Hardware Operating Status Data for
Modules” in this chapter.
Software Version
Default:
N/A
Range: (from module
firmware)
Format: Predefined
alphanumeric
Displays the version of PSAX system software
with which the modules’ firmware was released.
The software version is encoded in the module
firmware. Because not all modules require firm-
ware upgrades with every new PSAX system soft-
ware release, the software version that is dis-
played in this window may be lower than the
CPU system software that is currently running on
the PSAX system. See the most recent
Release Note
document for the latest software and firmware
lineup information.
Hardware Revision Default:
N/A
Range: (from module
firmware)
Format: Predefined
alphanumeric
Displays the version of the hardware for the
selected module.
Содержание PacketStar PSAX
Страница 24: ...Part 1 General ...
Страница 25: ......
Страница 44: ...Part 2 Console Operation ...
Страница 45: ......
Страница 182: ...Part 3 AQueView Operation ...
Страница 183: ......
Страница 404: ......
Страница 405: ...Part Number 534M0A8001D1 Copyright 2002 Lucent Technologies All rights reserved ...