Chapter 4 Configuring the Interfaces Using the Console Interface
Managing Frame Relay Interfaces
•
Viewing interface(s)
•
Deleting interface(s)
•
Viewing interface statistics
Configuring the Frame Relay UNI or NNI Interface
This section provides instructions for configuring a PSAX I/O module for the
frame relay user or network interface. Use the same window to configure
either interface. To set the values for the frame relay interface, perform the
steps in the following procedure.
Begin
After you apply the value
FrameRelayUni
or
FrameRelayNni
as the inter-
face type on a channel configuration window associated with one of the
modules above, the Frame Relay Interface Configuration window (see
Figure 4-11) is displayed. Table 1-1 describes the commands on the window.
Table 4-21 describes the fields on the window.
1
Select the values for the fields on this window from the values given in
Table 4-21.
2
To apply the interface configuration values, select the
Apply Interface
Configuration
command and press Enter.
The value
InService
is displayed in the [Operational Status]
field.
3
If your configuration requires you to bring the interface into service at
this time, do so by selecting the
Bring Interface Into Service
com-
mand. For more information on other configuration windows on which
you can bring interfaces into service, see the “Bringing One or More
Frame Relay UNI or NNI Interfaces into Service” procedure in this guide.
End
Содержание PacketStar PSAX
Страница 24: ...Part 1 General ...
Страница 25: ......
Страница 44: ...Part 2 Console Operation ...
Страница 45: ......
Страница 182: ...Part 3 AQueView Operation ...
Страница 183: ......
Страница 404: ......
Страница 405: ...Part Number 534M0A8001D1 Copyright 2002 Lucent Technologies All rights reserved ...