Chapter 3 Configuring Ports and Channels Using the Console Interface
Using the Equipment Configuration Window
3-6
255-700-467
PacketStar
®
PSAX 4-Port Voice 2-Wire Office Module User Guide
, Issue 1
Release 9.0.0
Alarm Status Values
The alarm status descriptions for the Alarm Status field on the Equipment
Configuration window are provided in Table 3-3.
Alarm Status
Default: No Alarm
Range: N/A
Format: Predefined
alphanumeric
Displays the present alarm condition of the mod-
ule. For the alarm status conditions, see the table
“Alarm Status Descriptions for Modules” follow-
ing this field description table.
SW #
Default: N/A
Range: (from module
firmware)
Format: Predefined
alphanumeric
Displays the version of PSAX system software
with which the modules’ firmware was released.
The software version is encoded in the module
firmware. Because not all modules require firm-
ware upgrades with every new PSAX system soft-
ware release, the software version that is dis-
played in this window may be lower than the
CPU system software that is currently running on
the PSAX system. See the most recent Release
Note document for the latest software and firm-
ware lineup information.
PEC
Default: N/A
Range: from module
bootloader
Format: Predefined
alphanumeric
Displays the product element code (PEC) used to
identify and order this type of module. The PEC is
encoded in the module bootloader.
Serial #
Default: N/A
Range: (from module
firmware)
Format: Predefined
alphanumeric
Displays the unique serial number of the individ-
ual module. The product serial number is
encoded in the module firmware. The format of
this field is the following:
PSAX System Rel. 6.5.0 and later: 12-digit num-
ber in the format:
YYVVDDnnnnnn
, where
YY
=
year of manufacture
VV
= vendor ID code (manu-
facturer and location)
DD
= date code of manu-
facture (either month or week depending on
vendor’s preference)
nnnnnn
= sequential num-
ber, which in conjunction with
YY
,
VV
, and
DD
,
creates a unique number for each hardware com-
ponent in the PSAX product line
For existing products with the 10-digit serial
number used in Rel. 6.5.0 or later systems, this
number is displayed with two preceding zeros.
PSAX Rel. 6.3.0 and earlier: 10-digit number. For
products with 12-digit serial numbers used in
Rel 6.3.0 or earlier systems, the first two digits
(
YY
) are not displayed.
Table 3-2. Field Descriptions for the Equipment Configuration Window (Continued)
Field Name
Field Values
Description