background image

Mitel SX200D ONS (77135)

          

C o n f i d e n t i a l

 

6

 

The above information is provided by Lucent Technologies as a guide. 

  See disclaimer on page 1 

Lucent Technologies 

O c t e l   M e s s a g i n g   D i v i s i o n

 

Programming when Enhanced Inband Signaling is not available or customer 
does not care to utilize the enhance inband signaling. 

Program the dial string for bin 500 as follows:  
   221*99*6*9 

(this will send Octel 50 9 + mailbox number) 

 

Ç

 

 

 

  

Hunt Group 
Access Code 

Program the dial string for bin 600 as follows: 

   221 *98*6*9 

(this will send Octel 50 8 + mailbox number) 

 

Ç

 

 

 

  

Hunt Group 

Access Code 

Speed dial programmed to allow for immediate recording used to record phone 

conversations. 

Program the dial string for bin 501 as follows: 

   221 *97*6*9 

(this will send Octel 50 7 + mailbox number) 

 

Ç

 

 

 

  

Hunt Group 

Access Code 

Note:  See Section 7.5 Record Telephone Conversation. 

ENHANCED INBAND SIGNALING DIAL STRINGS 

When *4 is in the dial string the Mitel 200D will replace it with the 
forward type access and the following reason codes: 

Valid index numbers are: 
1 - Forward Always 
2 - Forward on Busy 
3 - Forward No Answer 
4 - Forward Busy/No Answer 

When *8 is in the dial string the Mitel 200D dials out the ANI digits if the 
call originated over a trunk. If ANI digits are not allowed or not available, 
then no digits are sent. When the call is internal, the extension’s access 
code is dialed out. 

Program the dial string for bin 500 as follows:  
    221*9*4*6*8*9 
     

Ç

 

 

 

  

Hunt Group 
Access Code 

This will send Octel 50, Feature access code, Index number, mailbox number, 
calling number. 
Program the dial string for bin 600 as follows: 
     221*98*6*9   
      

Ç

 

Содержание Mitel SX200D Series

Страница 1: ...0D ONS Revised 5 6 99 Analog Ports Personal Computer Voice Board s Mitel SX 200D ONS SX 200 1 0 METHOD OF INTEGRATION Inband signaling is used for integration Integration is achieved via DTMF signals...

Страница 2: ...ITIONAL MATERIAL REQUIREMENTS A Personal Computer with a millennium compliant version of DOS is required to support the messaging system hardware and software Chapter 2 of the Installation Guide provi...

Страница 3: ...d Telephone Conversation3 9 LED 9 1 Flexible Forwarding requires Mitel Lamp Mail Enhanced Inband Signaling Audible Stutter Dial Tone 2 See section 5 4 3 See Section 7 5 Record Telephone Conversation 4...

Страница 4: ...t 1 Ten Tenant Group Number Day N1 N2 Assign Answer Point Pilot Number of the Octel 50 for designated time slot Tk Num Trunk ID Number Tk Name Names can be up to 8 characters FORM 17 HUNT GROUPS Creat...

Страница 5: ...igned as the feature access code 500 is the Call Forward Speed Dial Bin and 600 is the Immediate Login Speed Dial Bin The subscriber would forward the phone to 7500 and would retrieve messages by dial...

Страница 6: ...501 as follows 221 97 6 9 this will send Octel 50 7 mailbox number Hunt Group Access Code Note See Section 7 5 Record Telephone Conversation ENHANCED INBAND SIGNALING DIAL STRINGS When 4 is in the di...

Страница 7: ...Only 65 05 Call Forwarding External Only 62 5 5 CONFIGURING THE MESSAGE WAITING LIGHTS Assign an access code to feature 41 Send Message We recommend 4 This code will be used in Octel 50 Setup to set a...

Страница 8: ...band Parameters Total Number of DID Digits 10 Seconds to Wait for DID 2 Location of Inband Signaling Code 1 Number of Milliseconds to Wait for Digits 500 Code for Go to Immediate Record 7 Start at End...

Страница 9: ...G DEDICATED PORTS FOR MESSAGE WAITING LIGHTS The Mitel will automatically extinguish a station s Message Waiting Light MWL if the station connects with a member of the hunt group that set the MWL For...

Страница 10: ...ee way conference The Subscriber receives a call they which to record They hook flash get dialtone dial the speeddial code for immediate record 501 The SX200D connects to the Octel 50 sends the stored...

Отзывы: