Optical interface specifications
EN: Safety guide
............................................................................................................................................................................................................................................................
Lucent Technologies - Proprietary
See notice on first page.
365-312-879R5.1
Issue 1, August 2006
1 - 1 3
Metropolis
®
ADM (Universal shelf) - Connector types
The LKA6, LKA11, LKA13 and LKA14 optical tributary units are equipped with SC-type
connectors.
The LKA24, LKA25, LKA26, LKA27 and LKA47 core units as well as the LKA22 and
LKA23 optical tributary units are equipped with universal optical connectors, which allow
SC-, FC- and ST-types of connectors. The default connector type is SC-type.
All optical transceiver modules are equipped with LC-type connectors.
10 Gbit/s (STM-64)
LKA27
S-64.2b / S-64.3b
1550
SM (9/125)
1.6
+2
1 / I
LKA26
L-64.2b / L-64.3
1550
SM (9/125)
20
+13
1M / IIIb
LKA47
I-64.1r
1310
SM (9/125)
0.8
–1
1 / I
LKA29
S-64.2b / S-64.3b
1550
SM (9/125)
1.6
+2
1 / I
LKA28
L-64.2c / L-64.3
1550
SM (9/125)
2.5
+4
1 / I
LKA281
L-64.2c / L-64.3
1550
SM (9/125)
50.1
+17
1M / IIIb
LKA49
I-64.1r
1310
SM (9/125)
0.8
–1
1 / I
LKA350
(L-64.2c)
5
1550
SM (9/125)
25.1
+14
1M / IIIb
Fast Ethernet and Gigabit Ethernet
OM100BT-FX
100BASE-LX10
1310
SM (9/125)
0.15
–8
1 / I
OMGBE-SX
1000BASE-SX
850
MM (50/125)
0.4
–4
1 / I
OMGBE-LX
1000BASE-LX
1310
SM (9/125)
0.5
–3
1 / I
OMGBE-ZX
1000BASE-ZX
1310
SM (9/125)
3.2
+5
1 / IIIb
Notes:
1
SM: Single-mode fiber,
MM: Multi-mode fiber.
2
In the event of a disconnected or broken fiber, the "hazard level" defines the potential optical hazard at any accessible
location within an Optical Fiber Communication System (OFCS), based on the level of the radiant energy that could
become accessible.
3
Single fiber bidirectional SFP.
4
Not standards compliant (close to V-16.2).
5
Not standards compliant (close to L-64.2c).
Optical circuit pack or transceiver module Wavelength
Fiber type
1
(core/cladding
diameter)
Max. output
power
Hazard level
2
(IEC / FDA)
Apparatus code
Optical interface
type
[nm]
[µm]
[mW]
[dBm]