4
Define the cross-connection rate according to the used analyser signal
in the drop-down list box
Rate
. The following values are possible:
•
STS1
•
STS3
•
STS12
•
STS48
•
STS192
Please note that it is not possible to proceed to the next window
before selecting the cross-connection rate.
............................................................................................................................................................
5
Select
2 Way Point-to-Point
in the group box
Type of
Cross-connection
.
............................................................................................................................................................
6
Click on
Next>
to proceed to the next window.
Result:
Screen 2 of 3
opens.
............................................................................................................................................................
7
Click on
Select...
. to select the source tributary.
Result:
The
Ptn Grp
selection tab appears.
............................................................................................................................................................
8
Select the port to which the SONET analyser is connected.
Result:
In the list box
Tributary
on the right, the AIDs of all STSs
belonging to the respective port are displayed.
............................................................................................................................................................
9
Select the STS which shall be used as the source and click on the
Select
button.
............................................................................................................................................................
10
Select the destination port which is interface to the BLSR in the
Ptn
Grp
selection tab and the corresponding STS in the
Tributary
list box.
SONET test procedures
Point to point / Ring testing
Span / Ring testing
....................................................................................................................................................................................................................................
365-374-074
Issue a, April 2002
Lucent Technologies
8 - 4 3