Procedure
Proceed as follows to check the mean launched power:
............................................................................................................................................................
1
Connect the optical power meter to one output port of the optical
circuit pack to be tested.
............................................................................................................................................................
2
Measure the mean launched power at the connected port.
Important! The optical power meter must be set to the appropriate
wavelength range (see
“Value and wavelength ranges” (7-10)
). The
supported max. optical power limit of the optical power meter must
be greater than the maximum mean launched power of the measured
optical circuit pack to avoid damage.
............................................................................................................................................................
3
Check that the measured value is within the range shown below.
............................................................................................................................................................
4
Repeat the measurement for all optical ports.
Value and wavelength ranges
The following table provides the mean launched power value and
wavelength ranges of the optical circuit packs.
Circuit pack
Wavelength
range [nm]
Mean launched power
range [dBm]
OP40/1.3IOR1
1310
+5.0 ... +7.0
OP40/8650...9280XT
1550
-5.0 ... -3.0
OP10/1.3IOR1
1310
–6.0 ... –1.0
OP10/1.5IR1
1550
–1.0 ... +2.0
OP10/1.5LR1
1550
+10.0 ... +13.0
OP10/01...80/800G
1550
–6.2 ... –3.8
OP10/8650...9285XT
1550
-2.0 ... n/a
OP2G5/1.3SR4
1310
–10.0 ... –3.0
OP2G5/1.3LR4
1310
–2.0 ... +2.0
OP2G5/1.5LR4
1550
–2.0 ... +2.0
Optical power meter test
Stand alone test procedures
....................................................................................................................................................................................................................................
7 - 1 0
Lucent Technologies
365-374-074
Issue a, April 2002
E
N D
O F
S
T E P S
............................................................................................................................................................