Result:
The timing references are now used in the order of their quality
level.
............................................................................................................................................................
4
Select the port AID in the drop-down-list box
Assigned Port AID
.
Select in the drop-down list box
Not Connected
, if the respective
external timing signal should not be used or select
External Timing
Input Port 1
or
External Timing Input Port 2
depending on the tab
you have selected.
............................................................................................................................................................
5
Select in the drop-down list box
System Timing Reference Priority
the priority of the selected timing reference. The values can be
•
Disable
(initial value)
•
1
,
2, 3, 4, 5, 6, 7
, or
8
Make sure that all configured timing references have different
priorities assigned.
Result:
A priority list is created for the configured timing reference
signals. Initially the signal with the highest quality level is used
as timing reference signal. If it fails, the system switches to the
signal with the next lower quality level. If there are several
timing references with the same quality level, they are used
according to the priority list. If all possible timing reference
signals fail, the timing generator enters the holdover mode.
............................................................................................................................................................
6
Select the
Timing Port Mode Monitoring
. The values
Monitored
or
Not Monitored
are possible. This defines whether alarms are raised
for the timing signals or not.
............................................................................................................................................................
7
Select the
ASAP Name
Alarm Severity Assignment Profile. Via the
push-button
Browse...
you can select the alarm in the drop-down list
box. Click on
OK
to apply your setting.
By clicking on the push-button
Info...
you can call up a table with
details on the ASAPs.
Provisioning system parameters
Timing references
WaveStar
®
CIT installation and NE provisioning
....................................................................................................................................................................................................................................
6 - 2 2
Lucent Technologies
365-374-074
Issue a, April 2002