5
Enable or disable the use of
System Synchronisation Status
Messaging Mode
by selecting
QL Disable
or
QL Enable
. This means
that the selection of timing reference for the system timing is either
determined only by the provisioned priority list or by the quality level
given by the timing marker (SSM, Synchronization Status Message)
and secondly by the priority list. Click on the respective radio button.
............................................................................................................................................................
6
Select the clock mode in the group box
Clock Mode.
Click on the
respective radio button. You can select the following values:
•
Free Running
(The system is synchronized to the internal
oscillator.)
•
Locked
(The system is synchronized to a timing reference
signal.)
During normal operation in a network, the timing generator should be
locked to a timing reference signal as far as available. Normally the
free-running mode is used directly after the system start.
Result:
If you select
Free Running
the following warning window
appears: “Switching the timing clock from locked to free
running can temporarily result into transmission errors.”
............................................................................................................................................................
7
Select the
ASAP Name
Alarm Severity Assignment Profile. Via the
push-button
Browse...
you can select the alarm in the drop-down list
box. Click on
OK
to apply your setting.
By clicking on the push-button
Info...
you can call up a table with
details on the ASAPs.
............................................................................................................................................................
8
Apply the changes by clicking on
OK
or
Apply
. If you wish to
discard the changes, click on
Cancel
or
Undo
.
Provisioning system parameters
System timing
WaveStar
®
CIT installation and NE provisioning
....................................................................................................................................................................................................................................
365-374-074
Issue a, April 2002
Lucent Technologies
6 - 2 5
E
N D
O F
S
T E P S
.........................................................................................................................................................................................................................................................