363-206-204
Release 13 (TARP) Installation Tests
Issue 9 October 1998 9-7
NOTE
:
The login and password must be entered in uppercase as shown.
After a successful login, the DDM-2000 OC-3 will display the system
header followed by the alarm and status report:
Lucent DDM-2000 OC-3 Release a.b.c (circuit packs manufactured on
October 1, 1996, and later). This will be in a banner and additional text
describing the use restrictions and proprietary status will follow.
AT&T DDM-2000 OC-3 Release a.b.c (circuit packs manufactured before
October 1, 1996). This will be in a banner and additional text describing the
use restrictions and proprietary status will follow.
TID date time
/* Active Alarms and Status Report */
<
NOTE
:
Release a.b.c is the software release. TID is the Target Identifier of the
shelf. Date and time are the current system time of the shelf.
NOTE
:
Once logged on, the user can only issue commands to the on-line shelf. To
communicate with another shelf in the bay, the user will first have to termi-
nate the session with the current shelf. The session is terminated with the
log;
(LOGOUT) command.
4. Issue the command
init-sys:all;
(INITIALIZE-SYSTEM). This com-
mand will configure the DDM-2000 OC-3 with its default parameters.
NOTE
:
After cross-connections are entered use
init-sys:all
; with extreme
caution as it erases all cross-connects.
5. When initialization completes, repeat steps 2 and 3 to log back into the
shelf.
6. To change the TID, which is the name of the shelf, issue the command
set-ne
. When prompted with TID= enter the desired TID consisting of up
to 20 alphanumeric characters.
7. To change the number of lines displayed at a time (default = 24), issue the
command
set-link
(SET--LINK). Respond to the page length prompt
(pg) with the desired number of lines, between 3 and 150.
8. To change the time delay for alarms to be displayed or cleared, issue the
command
set-attr-alm
(SET-ATTRIBUTE ALARM). To eliminate any
alarm delay or clear delay, respond to the prompts with 0.
9. To change the time and date displayed, issue the command
set-date
(SET-DATE). Respond to the date and time prompts.
Содержание DDM-2000 OC-3
Страница 4: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Страница 9: ...363 206 204 Issue 9 October 1998 Lucent Technologies ...
Страница 10: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Страница 24: ...xxiv Issue 9 October 1998 363 206 204 ...
Страница 32: ...xxxii Issue 9 October 1998 363 206 204 ...
Страница 34: ...xxxiv Issue 9 October 1998 363 206 204 ...
Страница 58: ...1 ii Issue 9 October 1998 363 206 204 ...
Страница 74: ...2 iv Issue 9 October 1998 363 206 204 ...
Страница 143: ...363 206 204 Equipment and Rear Access Cable Installation Issue 9 October 1998 2 69 Figure 2 19 RJ 45 Plug and Face ...
Страница 144: ...2 70 Issue 9 October 1998 363 206 204 Equipment and Rear Access Cable Installation ...
Страница 192: ...3 46 Issue 9 October 1998 363 206 204 Equipment and Front Access Cable Installation ...
Страница 304: ...6 30 Issue 9 October 1998 363 206 204 Release 7 Installation Tests ...
Страница 330: ...7 24 Issue 9 October 1998 363 206 204 Release 8 Installation Tests ...
Страница 362: ...8 30 Issue 9 October 1998 363 206 204 Releases 9 and 11 Installation Tests Figure 8 2 DDM 2000 User Panel ...
Страница 395: ...363 206 204 Release 13 TARP Installation Tests Issue 9 October 1998 9 29 Figure 9 2 DDM 2000 User Panel ...
Страница 398: ...9 32 Issue 9 October 1998 363 206 204 Release 13 TARP Installation Tests ...
Страница 426: ...11 ii Issue 9 October 1998 363 206 204 ...
Страница 492: ...IN 14 Issue 9 October 1998 ...